Frequently Asked Questions; The Display Indicates The Following Messages Or Faults - Miele PDR 908 HP Operating And Installation Instructions

Heat-pump
Table of Contents

Advertisement

Frequently Asked Questions

With the help of the following guide minor faults in the performance of the
machine, some of which may result from incorrect operation, can be remedied
without contacting the Service Department.
This guide may help you to find the reason for the fault, and how to correct it.

The display indicates the following messages or faults

Message
 
The drum is empty
or the laundry is too
dry.
lights up after a
program has
been canceled.
Power outage. Pro-
gram stopped
Open bottom right
grille, clean the heat
exchanger
up at the end of a
program.
66
Possible cause and solution
This is not a fault.
In some programs, if the drum has been underloaded
or is empty, the program will be canceled. This can
also happen if the items are already dry.
 Open the door and check the laundry.
 Add items if necessary.
 Close the door to resume drying.
Dry individual items using the Time Dry program.
There has been a power outage.
 When power is restored, confirm with
 Touch the Start/Stop sensor control.
The heat exchanger's cooling fins behind the grille
can become blocked with dust and dirt drawn in from
the surrounding area and the airways can become
 lights
blocked with lint.
 Clean as described in "Bottom-right grille/heat
exchanger" under "Cleaning and care".
 Check and clean the filters in the loading area and
in the toe-kick.
 To delete the message: Touch the
control.
OK
.
 sensor
OK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents