The following item appears only when you set Fan Control Mode to [Thermal
Cruise Mode].
System Smart Fan Control [Enabled]
Allows you to enable or disable System Smart Fan Control. Configuration options:
[Enabled] [Disabled]
3-6
PWM/DC Voltage Output [255]
Sets the voltage allocated for Fan Control. Input value range:
[0~255]
Temperature source [PECI Agent 0]
Target Temperature [xx]
Input fan control target temperature. The values range from
0~127.
Tolerance of Temperature [xx]
Input tolerance of target temperature. The values range from 0~7.
Fan Out Start-up Value [xx]
Input fan out start-up value. The values range from 0~255.
Fan Stop Duty [Down to 0]
This item allows you to set the temperature for CPU Fan when
CPU temperature is out of the target temperature. Configuration
fields: [Down to 0] [To Fan out stop Vaule]
Fan Out Stop Value [xx]
The Fan out value decreases to this value if the temperature stays
below the lowest temperature limit.
Fan Out Stop Time [xx]
Determines the amount of time it takes Fan out value to fall from
the stop value to zero. The values range from 0~255.
Critical Temperature [xx]
Determines the time that Fan Out takes to decrease its value by
one step. The values range from 0~255.
Fan Out Step Up Time [xx]
Determines the time that Fan Out takes to increase its value by
one step. The values range from 0~255.
Fan Out Step Down Time [xx]
Determines the time that Fan Out takes to decrease its value by
one step. The units are intervals of 0.1 second. The values range
from 0~255.