Xantrex Freedom XC PRO Series Owner's Manual page 98

Inverter/charger
Table of Contents

Advertisement

Warning Messages
Table 14 Error codes displayed on the LCD screen
Error Code
Condition
Low battery voltage
shutdown is imminent
E01
depending on the setting,
see Freedom XC PRO Unit
on page 78.
High battery voltage
E02
shutdown
> 18.0 volts DC
AC output overload
E03
shutdown
E04
Over-temperature shutdown
E06
AC output overload warning
82
Mode
Check battery status and recharge if necessary.
Battery mode
Check for proper DC cable sizing.
(inverting)
Check for loose connections and tighten if necessary.
Battery mode
Check for external charging sources, such as a PV charger and
(inverting)
an over voltage alternator. Disconnect, if necessary.
Reduce the loads connected to the AC outlet of the unit.
Battery mode
Check appliances that have high-surge ratings and disconnect
(inverting)
if necessary.
Reduce the loads connected to the AC outlet of the unit.
Battery mode
Check that the ventilation grille is not blocked.
(inverting)
Check for ambient temperature and move the unit to a cooler
location whenever possible.
Battery mode
Reduce the loads connected to the AC outlet of the unit.
(inverting)
Action
Freedom XC PRO Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freedom xc pro 2000Freedom xc pro 3000818-2010818-3010

Table of Contents