Xantrex Freedom XC PRO Series Owner's Manual page 90

Inverter/charger
Table of Contents

Advertisement

Operating During Transition Between Grid Mode and Battery Mode
Setting Name
Battery Temperature
Custom Absorption
Voltage
Custom Float Voltage
Charger Current
(Freedom XC PRO
2000)
Charger Current
(Freedom XC PRO
3000)
Charger Ignition Control
Equalize Charging for
Flooded Battery
74
Setting
Default
Range of
Number
Value
CLD(Cold)
21
HOt
VRM(Warm)
HOT(Hot)
22
14.6
12.0 to 18.0
23
13.5
12.0 to 18.0
24
100
5 to 100
24
150
5 to 150
OFF(OFF)
26
OFF
AT0 (Auto-ON)
ENA (enable)
27
DIS
DIS (disable)
Values
Selecting Cold from Warm will increase charger voltage by 0.4V.
Selecting Cold from Hot will increase charger voltage by 0.8V.
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
The current setting value can be adjusted by 5A increments.
See Description of Ignition Control Features on page 40.
This setting is only available when Flooded battery type is
selected. It allows only one hour of equalize charging once.