Xantrex Freedom XC PRO Series Owner's Manual page 76

Inverter/charger
Table of Contents

Advertisement

Operating in Grid Mode
maintained at the default float voltage level for the selected
battery type or the voltage selected under Float Voltage on the
Custom Battery Settings menu.
Table 12 Preset Float Voltage Settings
Battery Type
Flooded
13.5
Gel
13.8
AGM
13.4
LFP
13.6
13.5 (default), changeable between 12.0
Custom
to 18.0
NOTE: The battery voltage can increase above the float voltage
when using an external charging device such as PV arrays, wind
turbines, and micro-hydro generators. Be sure to include
appropriate charge management equipment with all external DC
sources.
60
Preset Float Voltage
Equalize Charging
Many battery manufacturers recommend periodic equalize
charging to counter cell charge imbalance and capacity-robbing
electrolyte stratification. Equalizing helps to improve battery
performance and lifespan by encouraging more of the battery
material to become active.
Battery equalization is a controlled overcharging method that
mixes up stratified electrolyte and reactivates unused areas of the
plate material. Periodic equalizing can help to regularly restore
batteries to a full and healthy state of charge.
Consult the battery manufacturer's recommendation for equalize
charging settings. Sealed batteries should never be equalized.
Consult the battery manufacturer for optimal charging procedures
when using sealed batteries.
When Equalization is enabled, the battery is charged from bulk to
absorption, and then to the equalize phase. The Freedom XC
PRO will transition from the absorption phase to equalize at an
equalize current set to 10 amps.
After absorption, this constant current charge will continue until
the voltage has increased to 16 volts DC.
Equalization duration is fixed at one hour.
Freedom XC PRO Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freedom xc pro 2000Freedom xc pro 3000818-2010818-3010

Table of Contents