WARNING
ELECTRICAL SHOCK HAZARD
Tighten the nuts on the DC terminals properly. Loose
l
connections cause excessive voltage drop and may cause
overheated wires and melted insulation.
Do not over-tighten the nut on the DC input terminals
l
because damage to the DC input terminals may result. Use a
torque screwdriver to tighten the nut to a maximum torque of
80 in-lb (9 N-m) of force.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
NOTICE
REVERSE POLARITY
Check cable polarity at both the battery and the Freedom XC
l
PRO before making the final DC connection. Positive must be
connected to positive; negative must be connected to
negative. Check to see if the reverse polarity LED (see Step
6: Connecting the DC Cables) is not illuminated.
Reversing the positive and negative battery cables will blow
l
a fuse in the Freedom XC PRO and void your warranty.
Failure to follow these instructions can result in equipment
damage.
975-0799-01-01
Figure 12 DC Cable Connections
1
2
3
4
5
1
enclosure outline (DC compartment side view),
2
DC terminal nut
3
DC nut lock washer
4
cable ring lug
5
DC terminal
6
DC knockout hole
7
DC cable with heat shrink insulation covering the lug stem
NOTE: The DC cable lug stem must be fully insulated with the heat shrink.
12. Before proceeding, double check that the cable you have
just installed connects the positive DC terminal of the
inverter/charger to the disconnect/battery selector switch,
fuse holder, and that the other end of the fuse holder is
connected to the positive terminal of the battery.
Basic Installation Procedures
6
7
35