Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Connect ST leads on the yellow emergency transfer row/connecting block for each
4
emergency transfer telephone to the assigned terminal in the blue or white station
distribution field. The ST terminal leads should be terminated on the following pairs: 1,
4, 7, 10, 13, 16, 19, or 22 (the first pair of any 3-pair group).
5
Install the telephone:
Connect telephone to the information outlet.
Install patch cords/jumper wires between the media gateway side and the station
side of the station distribution field on the MDF.
Install Telephones Used for Emergency Transfer
and as Normal Extension (Trunk/Auxiliary Field)
Connect a pair of wires between the -48V and GRD terminals on the yellow emergency
1
transfer row/connecting block to the EM TRANS RELAY PWR terminal. See
''Connections for Telephone Used for Emergency Transfer and as Normal Extension'' on
page
198.
Connect CO trunk leads from the purple field to TC terminals on the yellow emergency
2
transfer row/connecting block for each trunk.
3
Connect CO trunk leads from the green field to TK terminals on the yellow emergency
transfer row/connecting block for each trunk.
4
Connect telephone leads from the purple analog line circuit pack row/ connecting block
to the LC terminals on the yellow emergency transfer row/connecting block for each
telephone.
Connect ST leads on the yellow emergency transfer row/connecting block for each
5
emergency transfer telephone to the assigned terminal in the blue or white station
distribution field.
Install the telephone:
6
Connect telephone to the information outlet.
Install patch cords/jumper wires between the media gateway side and the station.
May 2003
Installing and Wiring Telephones