DISTRIBUTION SYSTEMS - SECONDARY HYDRAULIC POWER SYSTEM
Hydraulic pump - Install (A.12.A.20 - F.10.A.15)
1.
Set the low pressure pump (1) into position on the
high pressure pump with the larger fitting toward the
front of the combine.
Turn in the two cap screws (2) to secure the pump.
Torque the cap screws to 58 - 63 N·m (43 - 47 ft. lbs
.).
Connect the hydraulic lines (3).
NOTE: The other two cap screws hold the low pressure
pump together.
2 4/7/2006
A.12.A / 17
1
10012183_977