DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
Hydraulic pump Variable displacement pump - Disassemble
(A.10.A.20.02 - F.10.A.25)
1.
Turn out two cap screws (1) and remove the low pres-
sure pump from the high pressure pump.
NOTE: The other two cap screws hold the low pressure
pump together.
2.
Slide the pump coupling (1) from the cavity. Remove
O ring (2) Turn out four cap screws (3).
3.
Separate the two sections of the pump (1) Remove
and discard the O ring.
2 4/7/2006
A.10.A / 53
1
20013879
2
20013864
3
20013865