Section 5 - Main Terminal Wiring; Main Terminal Description; Control Wiring For Single/Primary Operator - DoorKing 9500 Series Installation & Owner's Manual

Maximum security heavy-duty vehicular slide gate operator
Hide thumbs Also See for 9500 Series:
Table of Contents

Advertisement

5.1 Main Terminal Description

#1 - Jumper Wire - SW 1, switch 3 OFF (Single Operator Exit Loop Partial Open)
20
19 19 18 18
17 16 15 14 13 12 11 10 9 8
DANGER
HIGH VOLTAGE!
Main Terminal Input LEDs Note:
The LED that is above the main
terminal wiring input will light
when that terminal input gets
activated.
Operation of relay is dependent on
setting of SW 1, switches 4 and 5.
See page 16 and 17 for
DIP-switch function descriptions.
Relay contacts can be set for
Normally Open (NO) or Normally
Closed (NC) operation.
Contact rating is 1 amp maximum
at 24-volts DC.
3-Button Control Station Switch
Switch in RIGHT position ONLY
when using a 4-wire 3-button
control station with a
normally closed STOP circuit.
IMPORTANT:
Leave 3-button control
station switch in LEFT position when NOT
wiring a 3-button control station to control
board otherwise operator will NOT fuction.
26

SECTION 5 - MAIN TERMINAL WIRING

3-Button Station Switch
11
12
SW 1 is Upside-Down on Board
E N
O P
S E
C L O
NC
O P
S T
Factory
Setting
#9
#8
#7
#6
#5
7 6 5 4 3 2 1
SW 1, switch 3 is ON, terminal #4 functions as a normal FULL
open input. (Normal Setting). Single operator use ONLY.
4
SW 1, switch 3 is OFF, input to terminal #4
becomes the output from a plug-in loop
detector installed in the EXIT loop port of the
circuit board. A jumper wire is needed to open
and close the gate(s) for these applications:
#1
Terminal #4 jumpered to terminal #5 will PARTIALLY open an
automatic exit loop using a single channel plug-in loop detector
installed in the exit loop port.
For long gate applications. An input device connected to
5
terminal #5 will open the gate to the partial open setting,
See page 18 for more information.
9
This input ONLY fuctions when gate is fully opened or in
When gate is closing: SW 1, switch 7 is OFF, an input
to terminal #6 (N.O.) will reverse and open the gate.
Note: If the auto-close timer is ON, when gate reaches
the open position, timer will time out and
6
close the gate.
When gate is closing: SW 1, switch 7 is
ON, an input to terminal #6 (N.O.) will stop
the gate, then continue to close the gate when input is clear
(Used to help prevent tailgating vehicles from unauthorized
enrty). See page 17 for more information.
4404-018
#2
#4
Main Terminal
Input LEDs
Main Terminal #3 Note:
Exceeding 250 mA of power from this terminal
may cause the circuit board transformer to
overheat, causing intermittent problems.
SW 1 is Upside-Down on Board
the closing cycle.
SW 1 is Upside-Down on Board
Auxiliary Common
Terminal
Connect any low
voltage common
wire to these
2 terminals.
9510-065-D-5-20

Advertisement

Table of Contents
loading

This manual is also suitable for: