Page 1
Leave Manual with Owner Date Installed: Installer/Company Name: Circuit Board Serial Number Phone Number: and Revision Letter: Copyright 2012 DoorKing, Inc. All rights reserved. UL 325 Compliant Copyright 2009 DoorKing, Inc. All rights reserved.
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved.
1.8 Installation of Warning Signs SECTION 2 - AC/DC OPERATOR(S) POWER 2.1 High Voltage Wire Runs 2.2 High Voltage Power Connection and Battery Power SECTION 3 - ADJUSTMENTS 3.1 Circuit Board Description and Adjustments 3.2 DIP-Switch SW 1 and SW 2 Settings 20-21 9245-065-C-4-12...
Page 5
SECTION 6 - OPERATING INSTRUCTIONS 6.1 AC Power Switch and Reset Button 6.2 Shutdown Conditions Soft Shutdown Hard Shutdown 6.3 Manual Gate Operation SECTION 7 - MAINTENANCE AND TROUBLESHOOTING 7.1 Maintenance 7.2 Built-In Diagnostic Tests 7.3 Troubleshooting 37-38 7.4 Accessory Items 9245-065-C-4-12...
2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction. 3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier. 9245-065-C-4-12...
Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. 9245-065-C-4-12...
C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of, or supplied with, an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. E - An inherent audio alarm. 9245-065-C-4-12...
Non-compliant openings wider than 2 1/4”. Note: Install screened wire mesh to an Less than 2 1/4” existing Screened Wire Mesh. non-compliant gate and the adjacent fence that covers open gate position (See above). Gate Frame and Adjacent Fence Area 9245-065-C-4-12...
Do not let children operate the gate or play in the gate area. Separate This entrance is for vehicles only. Pedestrians must use separate entrance. Pedestrian Walkway Located so pedestrians cannot come in contact with the vehicular gate. 9245-065-C-4-12...
1.1 Gate Hardware 6 Inch 4 Inch DoorKing has a full line of Tandem V-wheels that are ideal for heavy gates and Guide Rollers with Protective Covers will ensure safe, reliable and long lasting gate operation. The gate must be Helps to minimize a pinch point on the properly installed and roll smoothly in both directions.
A chain tray is recommended for gates that are longer than 20 feet in length. The chain tray helps support the weight of the chain and reduce the chain stretching that occurs over time. DoorKing offers a chain tray kit that will fit any length gate (P/N 2601-270 10 ft.
Page 14
Steel or Aluminum. • 8,000 lb Max. Weight per Gate. • Single Operator - 100 Ft Max. Gate Length Dual Operators - 200 Ft Max. Total Gate Length • Chain tray recommended for gates over 20 ft. per gate. 9245-065-C-4-12...
Reverse loop conduit stand MUST be level! Pad depth is determined Conduit by soil conditions and local building codes. Minimum depth is 18 4” Minimum Above Ground inches. Wire Mesh Concrete Pad Reinforced concrete recommended. DoorKing recommends using 3/4-inch conduit. 9245-065-C-4-12...
S t a t a l p l e S a m DoorKing offers a thicker metal base plate without bolt holes to weld the gate operator directly to an existing metal stand. This thicker base plate will prevent any warping that can occur when welding metal plating.
1.6 Chain Tray Kit Installation A chain tray is recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray kit in sections to fit any length gate. (DoorKing P/N 2601-270 10 Ft. section)
1.7 Chain Installation Be sure to follow ALL 3 guidelines for either model 9245. Installing the chain in any other manner will cause excessive noise, chain idler wheel wear and chain stretching. Operator MUST be parallel to gate! Chain brackets MUST align with idler...
2.1 High Voltage Wire Runs The 9245 draws significant power and each operator should have a “Dedicated” circuit breaker at the power source. If power wiring is greater than the maximum distance shown, it is recommended that a service feeder be installed. When large gauge wire is used, a separate junction box must be installed for the operator connection.
MUST MATCH the operator To disconnect battery power specifications or DAMAGE will Keep wire clear of from solenoid, remove battery occur and VOID the warranty! all moving parts. module. Module ONLY fits one way when reinstalling, note the notch. 9245-065-C-4-12...
Adjust from 1 second maximum SW 1, switches 4 and 5 must (full counter-clockwise) to sensitivity. be set to control relay. See approximately 23 seconds Sensitivity SW 1 is Upside-Down on Board See page 23. next 2 pages for descriptions. (full clockwise). 9245-065-C-4-12...
Self-test mode. Operator MUST be disconnected from gate to run self-test. Normal Setting. Normal gate operation. Gate Opens Uphill MUST be ON if gate opens UPHILL. Normal Setting. Normal gate operation. Gate Opens Downhill MUST be ON if gate opens DOWNHILL. Spare Leave in the OFF position. 9245-065-C-4-12...
Page 23
Set to the OFF position for normal operation. Set to the ON position if gate OPENS in an UPHILL direction. Switch 2 Switch 3 Set to the OFF position for normal operation. Set to the ON position if gate OPENS in an DOWNHILL direction. Spare switch, leave in the OFF position. Switch 4 9245-065-C-4-12...
Limit AC power is Switch turned on, alarm will sound and operator will function. Main Terminal Partial Open Connection 20 19 18 17 16 15 14 13 12 11 10 9 8 7 4 3 2 1 9245-065-C-4-12...
If you are decreas- ing the sensitivity and the gate will not run properly, reduce the number of turns through the current sensor. Sample Turns Voltage and Phase Turns 208 Single Phase 230 Single Phase 1 Turn 2 Turns 9245-065-C-4-12...
3.6 AC Module Adjustment The 9245 model is equipped with an AC module that allows you to adjust the speed of the gate from 0 to 2 feet per second. To adjust the speed, simply rotate the speed control knob clockwise to increase the gate speed, or counter-clockwise to decrease the gate speed.
When the closing-direction reversing edge gets obstructed and the gate is traveling back to the open position and the opening-direction revering edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 34). Low Voltage Common: Common terminals for all the secondary entrapment protection device inputs. & 9245-065-C-4-12...
IF the closing-direction photo sensor is wired to the #6 main Photo Sensor Power Note: Photo sensors can be powered by the built-in terminal, a closing-direction photo beam that gets convenience outlets located on the operator (See previous page). obstructed will REVERSE the gate back to the open position. 9245-065-C-4-12...
Page 29
STOP, then continue in the same direction Place receiver in operator. Common after obstructed photo beam has been cleared until the gate cycle is complete. Wireless Note: Refer to the instruction sheet that comes with the receiver/transmitter for more specific wiring and mounting instructions. 9245-065-C-4-12...
A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that a licensed installer perform this work.
Terminal #4 jumpered to terminal #2 will FULLY open bi-parting gates using a dual channel plug-in loop detector installed in the exit loop port when using dual gate operators. DoorKing’s Remote alarm reset For long gate applications. An input device connected to station can be connected. See terminal #5 will open the gate to the partial open setting, page 31 for wiring.
White Com #2-Fully opens gate. 3-Button Control Station Safety Opening Device SW 1 is Upside-Down on Board DoorKing ONLY SW 1, Switch 3 MUST be ON except for dual operators or 9235 Model Operator exit loop partial open applications.
MUST be mounted in the line-of-sight of the gate operator. Gate Tracker - DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected. This system can keep track of gate operator cycle count, shorted inputs, loop detector problems, any forced entry attempts, if the gate has struck anything during the open or close cycle, power interruptions, etc.
20 19 18 17 16 15 14 13 12 11 10 9 8 4 3 2 1 operator only. DoorKing offers a free “Loop and Loop-Detectors Information Manual” PDF located at Doorking’s Green to primary operator web site for more information.
AC Power Switch - Powers the operator ON (I) (toggle up) or OFF (O) (toggle Left). - Used to turn off Reset Button RESET the entrapment alarm and to reset the operator after a HARD shutdown has occurred. Alarm Siren 9245-065-C-4-12...
Activation of a close command will run the gate to the closed position. Note: DoorKing operators have a built-in alarm reset push button mounted on the operator (See previous page for reset button location).
(Fail-Safe Operation) Disc brake will automatically disengaged when power is cut off to gate operator. Disc brake will automatically reengage after power has been restored but the gate operator WILL NOT cycle the gate until a command is given. 9245-065-C-4-12...
Check manual release for proper operation. Release ✓ Check secondary (external) reverse device(s) stop or reverse the Secondary Reverse Device gate when activated. ✓ ✓ Check set screws for tightness. Sprockets Complete check of gate and gate operating system. Complete System 9245-065-C-4-12...
5. If a three-button control station (open-close-stop) is connected to this gate operator, check for proper wiring. Only a DoorKing three button control station (P/N 1200-006 or 007) can be used with this gate operator. Others will cause a malfunction.
Page 40
Operator runs for 1 second and stops, two • There may be a problem with the current sensor on the circuit board. Replace the circuit board. short chirps are heard. 9245-065-C-4-12...
- Provides a remote station to reset an operator in a hard shutdown condition. Must be mounted in line-of-site of the gate and operator. Includes visual alarm light and audible siren. P/N 1404-080. Speed Bumps - Prefabricated six-foot speed bump reduces traffic speed through gate system. P/N 1610-150 9245-065-C-4-12...
Page 42
Model 9245 3 HP 1-Phase 208 / 230 VAC Shield Shielded Cable Orange 3 HP Motor 208 or Blue 230 VAC Red Red 1-Phase Black Ground MANUAL RELEASE White Mechanical Blue Brake 0 0 0 Black Speed AC Tech Brake...