Table 13. TCM/TFIO/TSW PROM boot blink codes (Continued)
Heartbeat
LED Blink
Error Code
Count Pattern
31
I2C Error
32
CPLD Error: Invalid Board
Type
33
CPLD Error: Invalid Geo
Slot Address
34
RAM Post Diagnostic Test
Failed
41
42
43
44
51
52

TCM/TFIO/TSW board boot blink codes

Table 14. TCM/TFIO/TSW board boot blink codes
Heartbeat LED
Blink Count
Error Code
Pattern
Note: The blink codes are in decimal format with a 3 second pause between code restarts. Using 127 as
an example, the blink pattern would be: 1 blink, pause, 2 blinks, pause, 7 blinks, long pause,
repeat.
111
BCUB
111
CCUB
112
BCPF
112
CCPF
113
BCRF
113
CCRF
114
BRUN
115
BTPF
115
CTPF
116
BTIF
116
CTIF
116
117
BBTF
112
SAN256N Director 2045-N16
Description
I2C error detected at board bringup; prevents memory
configuation
Board type invalid (0xff); caused by unseated board
Slot address invalid (0xff); caused by unseated board
Preliminary RAM test failed
Comprehensive DRAM Test (3.5 minutes)
Comprehensive Boot Flash Checksum
Comprehensive FCC1 Eth PHY Loopback
Comprehensive FCC2 Eth PHY Loopback
Boot Full DRAM Test
Boot Checksum Test (Board Boot) 52
Description
Boot - Inti UPM B Settings
Run Comprehensive Test - Init UPM B Settings
Boot - Program TCM FPGA
Run Comprehensive Test to Program TCM FPGA
Boot - Init TCM FPGA
Run Comprehensive Test - Init TCM FPGA
Boot - Jump to Application
Boot - Program TFIO FPGA
Run Comprehensive - Program TFIO FPGA
Boot - Init TFIO FPGA
Run Comprehensive - Init TFIO FPGA
Run Comprehensive - Init TFIO ASIC
Run TFIO Cyclone Autoboot