System Information - VBrick Systems 7000 Series Admin Manual

Network video appliances
Table of Contents

Advertisement

System Information

System Model
Hardware Revision
Boot Revision
OS Code Revision
Application Code Revision Displays the revision number of the application code running
Current Operational Mode Indicates the current operational mode of the VBrick. The
Temperature
Fan Status
Slot ID
Overloaded Count
CPU Utilization (%)
System Up Time
Total System Up Time
58
Displays the hardware model number of the appliance.
.
= Hardware Revision.
XX-YY
XX
Displays current boot revision.
Displays current OS code revision.
on the appliance.
following modes are supported:
• Run Mode – Normal operation.
• Diagnostics – User selected mode for running certain
VBrick diagnostics.
• Limited Run Mode – Limited operational mode (not
selectable). Normally occurs if a hardware problem exists
within the VBrick but it can still partially operate.
• Overloaded Mode – Limited operational mode (not
selectable). This mode occurs when the VBrick is
configured to handle more video than its operational
capacity. If this occurs, the VBrick needs to be
reconfigured to reduce the number of streams and/or data
rates. Under this condition, the appliance temporarily
reduces video traffic in order to maintain VBAdmin
functionality.
Displays the appliance temperature in Celsius (for example 50º
Celsius = 122º Fahrenheit). A temperature exceeding 72º C
will cause an alarm, a trap, and a log message; if the
temperature drops below 70° C the alarm and trap will clear.
When the temperature exceeds the maximum threshold, the
appliance will reboot and come up in Limited Run Mode;
when the temperature drops to an acceptable level, the
appliance will reboot and come up in normal Run Mode. The
temperature determines the fan speed as follows:
• If temperature > 50º C then fan speed = High.
• If temperature > 30º C then fan speed = Medium.
• If temperature < 30º C then fan speed = Low.
On, Off, Alarm.
Blade Server only. Indicates slot number of blade in server
chassis. Blades are numbered 1–11 from left to right.
Provides a count of the number of times the box has entered
the Overloaded Mode.
Shows average CPU utilization over the previous 10 seconds.
Total up time since last power cycle.
Aggregate up time since customer delivery.
= CPU Revision.
YY
© 2009 VBrick Systems, Inc.

Advertisement

Table of Contents
loading