TECHNICAL SPECIFICATIONS

Gas conditioning series CSS ®
Article number 230 V 50 Hz
Article number 115 V / 50-60 Hz
Gas outlet dew point
Dew point stability
Gas inlet temperature
Gas inlet water-vapour saturation
Gas flow
Ambient temperature
Storage temperature
Pressure
Total cooling capacity **
Number of gas inlets
Number of gas outlets
Condensate connection
Medium connections
Material of parts in contact with
medium
Operational
Mains connection
Power input
Device fuse
Electrical connection
Device protection class
Housing design
Device dimensions (H x W x D)
Electrical device standard
FPM = Viton ®
PVDF = Polyvinylidene fluoride
PVC = Polyvinyl chloride
FPM = Fluorinated rubber
PPH = Hard polypropylene
PTFE = Polytetrafluoroethylene
**Technical specifications with maximum values must be rated in consideration of total cooling capacity at 25 °C [77 °F] and an outlet dew point of 5 °C [41 °F].
*** 115 V / 50 Hz sample gas pump available as a special item
www.mc-techgroup.com
Version CSS-VC1
01G6050
01G6050a
Setting range: + 2 °C ..... + 7 °C [35.6 ... 44.6 °F],
factory setting: + 5 °C [41 °F]
Under constant conditions < ± 0.1 ° C [±0.18 °F]
Max. 180° C** [356 °F]**
Max. + 80 ° C** [176 °F]**
**Max. 250 Nl/h
10 to + 40 °C** [50 to 104 °F]**
-25 to + 65 °C [-13 to 149 °F]
0.7 bar to 1.4 bar abs.
Max. 144 kJ/h
1
1
1
Hose connection 4/6 mm
Heat exchangers: Glass, PVDF or stainless steel 1.4571
Hoses/screwed connectors: PTFE/PVDF
Universal filter e.g. FP-2T-D: PVDF, FPM, glass, PTFE
Front-installed filter FPF-0.1GF: PVDF, glass, FPM
Front-installed filter FPF-2-0.3GF: PVC, FPM, PPH
Peristaltic pump SR25.2: PVDF, Novoprene ®
Liquid particle e.g. CLF-5/W: PVDF, glass, FPM, PTFE
Sample gas pumps N3/5/9: PVDF, PTFE, FPM
Flow meter FM40: PVDF, glass, FPM, Hastelloy C4
Ball valve 3L/PV and 5L/PV: PVDF, FPM
Approx. 10 minutes.
230 V 50-60 Hz ±10 % or 115 V 50-60 Hz ±10 % ***
Max. 220 VA + max. 300 VA for sample gas pumps
6.3 A time-lag, 5 x 20 mm
-
Cold-device connector with 2 m cable
-
Single alarm connections (11 & 12-pole) or status alarm(s)
(6-pole) : maximum capacity of the relays 24 V 500 mA
-
mA-outlet : maximum load 500 Ohm, accuracy ±2 % of
measuring range end value for display indication
-
M&C Bus
-
Heated sample line : maximum length 10 m [≈ 82.81 ft]
IP20 to EN 60529
Steel housing for 19"- or wall mounting, painted RAL 7035
267.5 x 483 x 301.5 mm [≈ 10.53" x 19.02" x 11.87"]
(Portable version: 355 x 515 x 395 mm [≈ 13.98" x 20.28" x 15.55"])
EN 61010
CSS-VC-1.6 | 1.01.03
Version CSS-VC2
01G6055
01G6055a
**Max. 2 x 150 l/h
2
2