APPENDIX
Inverter Communication
Instructions
1
Inverter operation monitoring instruction [IVCK]
This instruction reads the operating status of an inverter and stores the read value in (d1) when an instruction
code set in the computer link operation of the inverter is specified.
IVCK
2
Example program
The following program reads the status (H7A) of the inverter (station number 0), stores the read value in M100 to
M107 of the programmable controller, and outputs it externally.
RUN monitor
SM400
3
4
5
Inverter instruction code
(H7A)
6
Programmable controller
internal devices
K2M100 = M100 to M107
Programmable controller
output devices
*: Make sure not to use devices being used in other control operations.
36
(s1)
(s2)
(d1)
(n)
(d2)
IVCK
K0
Inverter running
M100
Forward rotation
M101
Reverse rotation
M102
Alarm occurrence
M107
[Example 1] H02: During forward rotation
b7
0
M1 07 M 10 6 M1 0 5 M 1 04 M 10 3 M 1 0 2 M 1 0 1 M 1 00
Y7
Y6
H7A
K2M100
K1
M200
Y0
Y1
Y2
Y3
b0
0
0
0
0
0
1
0
Y 5
Y 4
Y3
Y 2
Y 1
Inverter status monitor: M100 to M107
Head bit device number for instruction execution status output
Communication channel: K1 to K4
Read value storage destination
Inverter instruction code (hexadecimal)
Inverter station number: 0 to 31
Status details
(as needed)
[Contents]
b0: RUN
b1: During forward
rotation (fixed)
b2: During reverse
rotation (fixed)
b3: SU (up-to-
frequency) (fixed)
b4: OL (overload)
(fixed)
b5: -
b6: FU (frequency
detection) (fixed)
Y 0
b7: ABC