2. INVERTER SETTINGS
Names of the Parts on
the Operation Panel
1

2.2 Parameter List

2.2.1 Inverter communication settings (required settings)

The following lists the parameters which are required to be set.
2
Description Parameter
Display
Pr.160
setting
Pr.117
3
Pr.118
Pr.119
Communication
setting
Pr.120
4
Pr.123
Pr.124
Pr.549
Pr.79
Operation
5
mode
setting
Pr.340

2.2.2 Parameter settings (for adjustment and operation)

6
Parameter
Number of PU
Pr.121
communication retries
PU communication
Pr.122
check time interval
14
Parameter List
Parameter Settings
Name
Extended function display
selection
PU communication station number
PU communication speed
PU communication stop bit
length
PU communication parity
check
PU communication waiting
time setting
PU communication CR/LF selection
Protocol selection
Operation mode selection
Communication startup
mode selection
Setting
value
Initial
Name
during
value
adjustment
9999
9999
Inverter Reset
Setting
Setting
Initial
value
value
value
(for the first
(for the second
inverter)
inverter)
9999
0
0
0
0
1
192
192
192
1
10
10
2
2
2
9999
9999
9999
1
1
1
0
0
0
0
0
0
0
10
10
Setting value
(for the first and
second inverters)
Set "9999" during adjustment, and set a value
1
3 (times)
from 1 to 10 during operation.
Set "9999" during adjustment, and set a value in
accordance with the system specification during
operation.
9999
0
5.0
0
(= 5 seconds)
1 to 9998: When it is necessary to monitor
Description
0: Displays simple mode and extended
parameters.
Maximum 16 inverters can be connected.
48 : 4800 bps
96 : 9600 bps
192 : 19200 bps
384 : 38400 bps
10: Data length: 7 bits
Stop bit: 1 bit
2: Even parity
Set with communication data.
1: CR: Provided, LF: Not provided
0: Mitsubishi inverter (computer link
operation) protocol
0: At power ON, the inverter is in the
External operation mode.
1 : Network operation mode
10 : Network operation mode
(Operation mode can be changed
between the PU operation mode and
Network operation mode from the
operation panel.)
Description
: During adjustment or when the
inverters do not communicate with the
programmable controller periodically
: When the inverters do not
communicate with the programmable
controller
absence of communications for a
certain time and stop the inverters
while they are communicating with the
programmable controller continuously.
When it is necessary to stop the motor
when the programmable controller
mode is changed from RUN to STOP.