Mitsubishi Electric MELSEC iQ-F Series Quick Connection Manual page 11

Programmable controller
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

1. PREPARATION
Preparatory Steps
Required Products
From the previous page
Step 5.
Cutting core wires
With a load bar
1. Insert each core wire through
the slot of the load bar.
Appearance of the load bar
2. Cut the core wires at the
edge of the load bar.
Cutting
3. Insert the load bar into a
connector.
4. Make sure that the load bar
is fully inserted to reach
the end of the connector.
System Configuration
Wiring
Without a load bar
1. Arrange the core
wires, and cut them to
approximately 1.5 cm.
2. Insert the core wires into a
connector.
3. Check that the core wires
reach the end of the
connector.
Connecting a
Terminating Resistor
Step 6.
Crimping the connector
using a crimping tool
Crimp the connector onto the cable
using the crimping tool.
Step 7.
Checking the self-made LAN cable
Check that there is no improper connection
or disconnection of the self-made LAN cable.
Step 8.
Adjusting and fixing the
modular cover
(When the pre-attached
type modular cover is used)
[Before]
[After]
1
2
3
4
5
6
11