Configure Sensor Alarms; Configure Exceptions Alarms - HIKVISION DeepinMind Series User Manual

Hide thumbs Also See for DeepinMind Series:
Table of Contents

Advertisement

2. Select a camera.
3. Check Enable.
4. Set the video tampering area. Drag on the preview screen to draw the customized video
tampering area.
5. Set Sensitivity (0-2). 3 levels are available. The sensitivity calibrates how readily movement
triggers the alarm. A higher value more readily triggers the video tampering detection.
6. Set the arming schedule. Refer to Configure Arming Schedule .
7. Set linkage actions. Refer to Configure Linkage Actions .

5.1.4 Configure Sensor Alarms

Set the handling action of an external sensor alarm.
Steps
1. Go to System → Event → Normal Event → Alarm Input .
2. Select an alarm input item from the list and click
3. Select the alarm input type.
4. Edit the alarm name.
5. Check Input.
6. Set the arming schedule. Refer to Configure Arming Schedule .
7. Set linkage actions. Refer to Configure Linkage Actions .

5.1.5 Configure Exceptions Alarms

Exception events can be configured to take the event hint in the Live View window and trigger
alarm output and linkage actions.
Steps
1. Go to System → Event → Normal Event → Exception .
2. Optional: Enable the event hint to display it in the live view window.
1) Check Enable Event Hint.
2) Click
to select the exception type(s) to take the event hint.
Network Video Recorder User Manual
.
57

Hide quick links:

Advertisement

Table of Contents
loading