The time you set to record before the scheduled time or event. For example, when an alarm
triggers the recording at 10:00, and if you set the pre-record time as 5 seconds, the camera
records at 9:59:55.
Post-record
The time you set to record after the event or the scheduled time. For example, when an
alarm triggered recording ends at 11:00, and if you set the post-record time as 5 seconds, it
records till 11:00:05.
Stream Type
Main stream and sub-stream are selectable for recording. When you select sub-stream, you
can record for a longer time with the same storage space.
Expired Time
The expired time is period for a recorded file to be kept in the HDD. When the deadline is
reached, the file will be deleted. If you set the expired time to 0, the file will not be deleted.
The actual keeping time for the file should be determined by the capacity of the HDD.
Redundant Record/Capture
By enabling redundant record or capture you save the record and captured picture in the
redundant HDD.

4.1.2 Enable the H.265 Stream Access

The device can automatically switch to the H.265 stream of IP camera (which supports H.265 video
format) for the initial access.
Go to Camera → More Settings → H.265 Auto Switch Configuration to enable the function.

4.1.3 ANR

ANR (Automatic Network Replenishment) function enables the IP camera to save the recording
files in the local storage when the network is disconnected, and when the network is resumed, it
uploads the files to the device.
Steps
1. Log in your device via web browser and go to Configuration → Storage → Schedule Settings →
Advanced .
2. Check Enable ANR.
3. Click OK.

4.1.4 Manual Recording

You can click
to manually start/stop recording videos at live view.