Bosch SCT 815 Original Operating Instructions page 16

Adjustment device
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
en | 16 | SCT 815
2
1
(1) Preassembled tool holder
(2) Knurled screw
5. Position the mount for the line laser
holes over the tube connectors on the guide tubes.
4 Nm
1
3
4
2 2
5
(1) Line laser mount
(2) Tube connectors on guide tubes
(3) Countersunk screw
(4) Washer
(5) Hex nut
6. Use the countersunk screws
(5)
hex nuts
to secure the mount for the line laser on
the tube connectors at 4 Nm.
7. Slide the prismatic reflector
1 689 989 475 | 2020-05-01
2
1
(1)
with the
(3),
(4)
washers
and
(1)
onto the tool holder.
1
(1) Prismatic reflector
8. Secure the plastic screws
The plastic screws are intended as a stop so the
prismatic reflector cannot slide off the tool hold‐
er by accident. 3 plastic screws are included in
the scope of delivery. The third plastic screw is
intended as a spare.
1 1
(1) Plastic screws
---Separator---
3.2
Checking the accuracy of the inclina‐
tion measurement (before each cali‐
bration)
 Before each calibration, check the accuracy of the in‐
clination measurement. Use reverse measurement. To
do this, place the measuring instrument on a table
and measure the inclination. Turn the measuring in‐
strument by 180°, and measure the inclination again.
The maximum permissible difference between the
numbers indicated is 0.3°. In case of a greater devia‐
tion, recalibrate the measuring instrument. To do this,
select CAL in the settings. Follow the instructions on
the display. We recommend a check of the accuracy
and, if necessary, a calibration of the measuring in‐
strument after severe temperature changes and im‐
pacts. After a change in temperature, give the measur‐
ing instrument some time to return to a normal tem‐
perature before performing the calibration.
---
(1)
on the tool holder.
Robert Bosch GmbH

Advertisement

Table of Contents
loading