EPSON Perfection1200
5.1 Firmware Update
Firmware update is required after replacing the Main Board. The following
items are necessary for the update:
Update Program Disk (P10B01W)
PC
SCSI or USB Cable ("S" or "U" depending on the model type)
5.1.1 Operating Environment for the
Update Program
Supported OS:
Windows98 exclusive
Operating Condition:
TWAIN Driver (enclosed with the scanner) must
have been installed.
5.1.2 Installation of the Update Program
Install the Firmware Update Program according to the following steps:
1. Double-click the set-up file "P10B01W.exe" in the Update Program disk,
and the following screen will appear.
Figure 5-1. Setting up P10B01W (1)
Firmware Update
2. Confirm the installation folder and click OK , and the program will be
automatically installed.
5.1.3 Updating Method
1. Connect the scanner to the PC using SCSI or USB cable, and turn on the
scanner. Confirm that the status lamp (green) is on, or lift up the document
cover to confirm the fluorescent lamp (white) is on.
2. Select Start, Program , Program for Production , and P10B01W to
execute the program.
3. When a screen shown in Figure 5-2 appears, select one of the products
you wish to update by clicking the product name or using the cursor keys.
4. Click Next or press Enter .
Firmware Update
Figure 5-2. P10B01W (2)
Revision B
55