5. Remove 4 screws (CP, M2.5x6) located around the I/F connector behind
the scanner body and one screw(CP, M3x5).
6. Remove each cable from CR motor connector (CN5), carriage FFC
connector (CN4) and power supply unit connector (CN6).
7. Lift up the front part of the main board, pulling it toward you, and remove
the connector from the scanner body. Then, remove the main board.
CP(M2.5x6)
Figure 4-26. Main Board Removal (2) (SCSI)
Disassembly and Assembly
CP (M3x5)
Disassembly Procedures
Carriage FFC
Connector
CR Motor
Connector
Figure 4-27. Main Board Removal (3) (SCSI)
Figure 4-28. Main Board (SCSI)
Revision B
Power Supply Unit
Connector