6. Remove the inverter lamp connector from the inverter board.
7. Remove one black screw and a connector (2-pin) for CCD sensor board,
then remove the inverter board.
8. Remove the inverter lamp from the upper cover.
When installing the inverter lamp, locate the wire as it is
shown in figures 4-9 and 4-10.
Disassembly and Assembly
Figure 4-9. Disassembly of the Carriage Unit (3)
Disassembly Procedures
Inverter Board
Connector
Connector (2-pin)
Upper Cover
Inverter Board
Figure 4-10. Inverter Lamp Removal
Revision B
Black screw
Inverter Lamp