Left Steering Hose Installed on Steering Orbital
FIGURE 6.
Left
Install an ORFS M/M/F swivel run tee fitting in the open port of the steering orbital.
2.
Models 275/325 - Install a -10 ORFS M/M/F swivel run tee adapter fitting (P/N 333-0012-031).
Larger models - Install a -8 ORFS M/M/F swivel run tee adapter fitting (P/N 333-0012-028).
Note:
Do not tighten the tee fitting. It may be necessary to adjust it when the SmarTrax hose is installed.
Connect the machine's left steering hose to the opposite end of the installed tee fitting.
3.
Models 275/325 only - Install and tighten a -10 ORFS (F) to -8 ORFS (M) reducer fitting (P/N 333-0012-
4.
032) in the 90° end of the installed tee fitting.
Note:
It may be necessary to install a -8 ORFS M/F 45° swivel elbow fitting (P/N 333-0012-102) or -8
ORFS M/F 90° swivel elbow fitting (P/N 333-0012-067) on one end of the hydraulic hose to
achieve the following SmarTrax hose connections.
Install one end of the supplied hydraulic hose (P/N 214-1000-909) on 90° end of the installed tee fitting.
5.
Left Steering Hose Installed on SmarTrax Valve
FIGURE 7.
Connect the other end of the installed hydraulic hose to the fitting installed in Port A of the SmarTrax valve
6.
(P/N 334-0003-089).
Tighten all hose ends and the installed tee adapter fitting connection to the steering orbital.
7.
Manual No. 016-5032-020 Rev. A