Operation - Quick BTR140 Series Installation And Use Manual

Retractable thruster
Table of Contents

Advertisement

Available languages

Available languages

6 - Operation

6.0 - Option selection Dip-Switch
SELECTION
FUNCTION
1
Reserved (always keep off)
Informs the CAN control station that the thruster is in the bow (OFF)
2
Informs the CAN control station that the thruster is in the stern (ON)
3
Reserved (always keep off)
4
Reserved (always keep off)
FACTORY SETTING: 1 = OFF , 2 = OFF , 3 = OFF , 4 = OFF
6.1 - Actuator current rotary switch
The ten selectable steps (from 0 to 9) allow you to set a percentage (see table) regarding the maximum current/load allowed
for the actuator in use.
ROTARY SWITCH
POSITION
0
1
2
3
4
5
6
7
8
9
Should a setting different to the factory one be requested, carry out the following operations:
1) Turn the arrow of the rotary switch to the desired position with the board not powered.
2) When the board is powered, the percentage corresponding to the selected position will automatically be set.
If the maximum current/load is too low compared to the real operating requirements, may intervene protections against high
absorption of the actuator in closing and opening the retractable, with flashing 1 and 7 errors.
36
MAXIMUM CURRENT/
LOAD %
28%
36%
44%
52%
60%
68%
76%
84%
92%
100%
BTR140 INSTALLATION AND USE MANUAL - REV002A
BTR140
EN
DIP-SWITCH
ON
1
2 3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1 2
3
4
ON
1 2 3
4
ON
1 2 3 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Btr1403012Btr1404012

Table of Contents