Fig. 7: Installation plan for Chlorinsitu
20.
Connect the activation contact to the control cabinet - via the
housing section (H). Remove the wire jumper between the
contacts.
21.
Optional: Connect the "Low flow contact" outlet of the
external product storage tank to the control cabinet - via the
housing section (H). Remove the wire jumper.
22.
Optional: Connect the "Level too high" level switch of the
external product storage tank to the control cabinet - via the
housing section (H).
23.
Connect the "Start/stop level" level switch of the external
product storage tank to the control cabinet - via the housing
section (H).
24.
Connect the "Level too low" level switch of the external
product storage tank to the control cabinet - via the housing
section (H).
25.
Connect the Ethernet cable to the control cabinet - via the
housing section (H).
26.
Assemble and install a two-pin mains switch or emergency
stop switch in the immediate vicinity of the system or use
another suitable isolating device.
27.
Install a mains cable between the internal power supply and
the mains switch or the emergency stop switch - via the
sleeve section (J).
Ø 900
Ø 1645
®
IIa 650 ... 2500 g/h with brine storage tank - all dimensions in mm
Installation and assembly
800
1500
A2397