Menu Name
Minimum Password to Read
(Menu Index)
(None, User, Manager, Technician)
Set|Compressor
CmpMtrVlvTm:
CmpMnOnTm:
CmpMnOffTm:
ClOATLckSpt:
CmpHtOATLck:
CmpHtEWTLck:
SrcTmpDiff:
RevVlvTmr:
Set|Timers
EWFlwTmSpt:
MnStgTmSpt:
ClStgTmSpt:
HtStgTmSpt:
NgtPrgTm:
Set|Dehumid
SpcRHSpt:
SpcRHSptOffDif:
KeyDehumEn:
DehumType:
DehumStgDn:
PassDehumFBPD:
NetDehumEn:
SpcRHEn:
OutRHEn:
EnthSel:
DehumFanSpt:
DehumLTmpSpt:
Set|DAT
DATClSpt:
DATHtSpt:
DAEconLL:
DAMechLL:
RehtLLStTime:
DAHiLim:
DATRstClSel:
MnDATClSpt:
MxDATClSpt:
MnDATClCntSpt:
MxDATClCntSpt:
DATRstHtSel:
MnDATHtSpt:
MxDATHtSpt:
MnDATHtCntSpt:
MxDATHtCntSpt:
DATClDb:
DATHtDb:
RstReHtSel:
MnDATReHtSpt:
MxDATReHtSpt:
MnDATReHtCntSpt:
MxDATReHtCntSpt:
Set|ElectricHeat
ElHtPropGn:
ElHtIntgGn:
ElHtStgTmSpt:
MnElHtFanOnTm:
SupElHtSel:
Set|OutdoorDamper
OADMnPos:
OADMnPosMdSpd:
OADMnPosLwSpd:
SpcCO2Lim:
EconOASpt:
EconDdDiff:
EconEnthSpt:
EconEnthDiff:
OAMxPos:
OALockEn:
OALockSpt:
OATSpt:
EconEn:
OM 1280-2 • MICROTECH UNIT CONTROLLER
Minimum Password to Write
(None, User, Manager, Technician)
"RO" if Read Only
N
N
N
N
N
N
N
T
N
N
N
N
N
N
T
N
T
T
T
N
T
T
T
T
T
N
N
N
N
T
N
N
T
T
T
T
N
T
T
T
T
T
T
T
T
T
T
T
N
N
T
T
N
N
N
N
N
N
T
N
T
N
N
N
N
N
Appendix – Local User Interface (LUI)
Help Text
T
Motorize valve delay.
T
Compressor minimum on time.
T
Compressor minimum off time.
T
Comp clg disabled when OAT < setpt.
T
ASHP: Comp htg disabled when OAT < spt.
T
WSHP: Comp htg disabled when EffEWT < spt.
T
Min water temp diff for hydro ht & cl.
RO
Rev vlv chgs this long after comp start.
M
Flow time before hydro ht/cl available.
M
Minimum state transition time.
M
Min time before clg stg chg can occur.
M
Min time before htg stg chg can occur.
M
Night purge state time.
M
Space relative humidity setpoint.
M
Space relative humidity setpoint diff.
M
Keypad dehumidification enable.
T
Active adds reheat.
T
Stg dn dehum when in coil temp < spt.
T
F&B damper max for passive dehum.
RO
Network dehumidification enable.
T
Space humidity sensor enable.
T
Outdoor humidity sensor enable.
T
Select outdoor enthalpy calc strategy.
T
Initial dehumidification fan speed.
T
No dehum when cntrl temp < this spt.
M
DAT cooling setpt when not reset.
M
DAT heating setpt when not reset.
T
DAT Clg LL during non-comp cooling.
T
Discharge air mech low limit setpt.
T
Reheat to ReheatLL time.
T
Discharge air high limit.
T
Source of DAT Clg reset control.
T
Min input to DAT clg reset calc.
T
Max input to DAT clg reset calc.
T
Min DAT clg reset setpt.
T
Max DAT clg reset setpt.
T
Source of DAT Htg reset control.
T
Min input to DAT htg reset calc.
T
Max input to DAT htg reset calc.
T
Min DAT htg reset setpt.
T
Max DAT htg reset setpt.
T
DAT cooling deadband.
T
DAT heating deadband.
T
DAT reset reheat select.
T
Min input to DAT reheat reset calc.
T
Max input to DAT reheat reset calc.
T
Min DAT reheat reset setpt.
T
Max DAT reheat reset setpt.
T
Electric heating proportional gain.
T
Electric heating integral gain.
T
Min time elect ht stg chg can occur.
T
Min fan on after leaving elect heat.
M
Allow elect heat to supplement primary.
M
Min OAD for CO2 and fan at high speed."
M
Min OAD when space fan at medium speed."
M
Min OAD when space fan at low speed."
M
Space CO2 setpoint.
M
Economizer outdoor air setpoint.
T
Economizer IA/OA temperature differential.
M
Economizer enthalpy setpoint.
T
Economizer enthalpy setpoint differential.
T
Maximum Outdoor Air damper position.
M
OA damper low temperature lockout.
T
OA damper low temp lockout setpoint.
M
Economizer OAT setpoint.
M
Keypad economizer enable.