JRC JHS-770S Instruction Manual page 117

Marine vhf radiotelephone
Hide thumbs Also See for JHS-770S:
Table of Contents

Advertisement

6.3.1
Alarm list
The following list shows the types of system alarm and contents.
Alarm
Display
Number
001
TRCVR high temp
002
TX PLL unlock
003
RX PLL unlock
004
WKR PLL unlock
005
TRCVR memory
006
CTLR1 memory
007
CTLR2 memory
008
CTLR3 memory
009
CTLR4 memory
010
CTLR5 memory
011
CTLR1 SIO
012
CTLR2 SIO
013
CTLR3 SIO
014
CTLR4 SIO
015
CTLR5 SIO
016
GPS SIO
017
Serial printer1
018
Serial printer2
019
Parallel printer
020
MMSI lost
021
Own CTLR ID
022
Own CTLR SIO
023
PTT line
024
TRCVR PS (DC/DC)
025
TRCVR PS (FUSE)
026
Abnormal RF power
027
POWER-OFF failure
Contents
Detected the abnormally high temperature
in the transceiver.
Detected PLL Unlock in the transmitter.
Detected PLL Unlock in the receiver.
Detected PLL Unlock in the watch-keeping
receiver.
Detected the transceiver memory error.
Detected the memory error in controller 1.
Detected the memory error in controller 2
or channel selector 2.
Detected the memory error in controller 3
or channel selector 3.
Detected the memory error in controller 4
or channel selector 4.
Detected the memory error in controller 5
or channel selector 5.
Detected the serial communication error
in controller 1.
Detected the serial communication error
in controller 2 or channel selector 2.
Detected the serial communication error
in controller 3 or channel selector 3.
Detected the serial communication error
in controller 4 or channel selector 4.
Detected the serial communication error
in controller 5 or channel selector 5.
Detected the GPS communication error
Detected an alarm of the printer 1.
Detected an alarm of the printer 2.
Detected an alarm of the Centronics type
printer connected to the transceiver.
The MMSI has not been registered yet, or
has been lost.
Detected the ID error in the controller
displaying this message. It is recorded on
the alarm history as alarm of No. 011-015.
Detected the loss of communication with
the transceiver via RS-485 lines. It is
recorded on the alarm history as alarm of
No. 011-015. However, it may not be
recorded on the alarm history.
Detected malfunction regarding PTT line.
Detected DC/DC power supply error.
Detected PS error at the RF circuit, e.g.
the fuse blown.
Detected malfunction in the transmission
circuit or the duplexer connection.
Detected malfunction regarding power
supply control circuit.
Maintenance & Inspection
Troubleshooting Procedure
Stop transmission, or
reduce the power to 1W
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Check the printer power or
the paper empty.
Check the printer power or
the paper empty.
Check the printer power or
the paper empty.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Please contact JRC or
our agency.
Check or replace the fuse
(F3) on the CBD-7701 T/B.
Please contact JRC or
our agency.
Turn OFF the power switch
in the transceiver or of the
external power source, and
then please contact JRC or
our agency.
6-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jhs-780d

Table of Contents