3
Table 3-2
9061 Function Submenu List — continued
• Output Line
• Restore Defaults
3-22
9061 Function Submenu List and Descriptions
(continued)
Allows selecting the line location of the AFD data within the video signal
Ancillary Data space.
(Range is 9 thru 41)
Note: • Although the output line drop-down will allow any choice within the
9 thru 41 range, the actual range is automatically clamped (limited)
to certain ranges to prevent inadvertent conflict with active picture
area depending on video format. See Ancillary Data Line Number
Locations and Ranges (p. 3-8) for more information.
• The card does not check for conflicts on a given line number.
Make certain the selected line is available and carrying no other
data.
Restore Defaults provides default restore of all user settings described in
the remainder of the AFD function description.
When Confirm is clicked, a Confirm? pop-up appears, requesting
confirmation.
• Click Yes to proceed with restore defaults.
• Click No to reject restore defaults.