2.10.2 SERVICE-10-2 Footplate Shroud Replacement

Please follow SERVICE-10 Front Top Shroud Repair to remove the shroud, then:
1. Press the front top shroud downwards by hand.
2. Allow the shroud to disengage from the center locking pin.
3. Gently bend the shroud downwards to disengage from the right-side locking pin.
4. Remove the locking pin spring on the left side.
5. Take the footplate shroud off.
❖ When reassembling, please follow the exact reverse sequence of these steps.
• Step 5. When replacing the footplate spring, do not use too much force.
• This might deform it and cause a loss of function.
• Please do not leave the footplate shroud off, it must be replaced. Leaving it off is dangerous
for the user and may also damage the scooter.
• After removing the footplate spring, keep it aside carefully. The re-installation of the spring is
more complicated. Refer to the following figures for instructions for its replacement.
1654773~A