Service-01-3 Starter Vr Repair - Invacare Scorpius Series Service Manual

Table of Contents

Advertisement

Scorpius
Service Manual
2.1.2

SERVICE-01-3 Starter VR Repair

Please refer to Service Procedures SERVICE-01 Steering Shroud Repair
steps as follows:
1. Find the starter VR connector (figure on the right).
2. Re-connect the starter VR (figure on the right).
3. If function is not restored, go to Starter VR Replacement below.
Starter VR Replacement:
Refer to Service Procedures SERVICE-01 Steering Shroud Repair steps as follows:
1. Remove the screws (16 mm, 2 pcs) on the handle and steering head front shroud.
2. Remove the steering head front shroud and set it aside carefully.
3. Remove the starter rod connector on the board.
4. Remove the screws (12 mm, 2 pcs) of steering bar and starter VR.
5. Take off the starter VR and connector.
6. Take out the starter controller and replace it with a new one.
❖ After the replacement of parts or re-installation, please follow the exact reverse sequence for reassembly.
❖ If function has not been restored, go to SERVICE-01-1 Top Control Panel Repair.