Navistar MaxxForce DT Diagnostic Manual page 24

Aftertreatment symptom-based diagnostic and inspection manual
Hide thumbs Also See for MaxxForce DT:
Table of Contents

Advertisement

DIAGNOSTIC MANUAL
Step
8
Do Onboard Filter Cleanliness Test (OBFCT) to clear active
aftertreatment fault code(s). Using Electronic Service Tool (EST)
with ServiceMaxx™ software, go to Tests > KOER Aftertreatment
Tests > Onboard Filter Cleanliness Test. While OBFCT is running,
check the following components for exhaust leaks, and verify all
fasteners, brackets, and clamps are secure and undamaged:
Low Pressure (LP) turbocharger outlet pipe
Exhaust Back Pressure Valve (EBPV)
Flexible mesh pipe to DOC inlet
Inlet to DOC
Were all components free of exhaust leaks, and all fasteners,
brackets, and clamps secure and undamaged?
Step
9
Check for a failed Air Management System (AMS) actuator.
1. Using EST with ServiceMaxx™ software, go to Tests
2. Go to Sessions > Performance and select the record
3. Go to Tests > KOER Tests > Air Management Test.
When Air Management Test is complete, stop recording. Use
the playback feature in ServiceMaxx™, and graph the following
signal values:
Signal Values:
Mass Air Flow (MAF) mean value
Intake Manifold Pressure (IMP)
Exhaust Gas Recirculation (EGR) valve position
Does snapshot match Graph 1 or Graph 2 page 51?
20
Action
Action
> Load Test Specific Session and verify Load Test
Specific Session is unchecked.
snapshot icon from the toolbar.
https://www.truck-manuals.net/
Decision
Yes: Go to step 9
No: Repair exhaust leak
or repair failed fastener,
bracket, or clamp. After
repairs are complete, go
to step 9.
Decision
Graph 1: Go to step 10A
Graph 2: Diagnose and
repair failed actuator
(See Performance
Diagnostics section
in Engine Diagnostic
Manual). After repairs
are complete, retest for
original problem.