Navistar MaxxForce DT Diagnostic Manual page 103

Aftertreatment symptom-based diagnostic and inspection manual
Hide thumbs Also See for MaxxForce DT:
Table of Contents

Advertisement

To prevent personal injury or death, do not exceed local speed limit laws or drive too fast
for conditions when performing Lug Down Test.
Step
8A
Using EST, go to Sessions > Performance. Find an open
stretch of road in order to perform Lug Down Test. When
driving conditions are safe, select the record snapshot icon
from the toolbar, and perform Lug Down procedure below:
1. Select a suitable high range gear (Example: In
a 10 speed gearbox, select the 8th speed).
2. Allow engine speed to drop to 1000 rpm.
3. Press accelerator pedal fully to the floor, and
accelerate to rated engine speed.
After Lug Down Test is complete, stop recording and save
snapshot.
Step
8B
Check for low fuel rail pressure. Using EST with
ServiceMaxx™ software, use the playback feature and
graph the following signal values from Lug Down Test:
Signal Values:
Engine Speed
Fuel Rail Pressure (FRP)
Fuel Rail Pressure Desired (FRPD)
Compare snapshot to Graph 3 and associated Graph
Analysis page 124.
Is FRP signal operating as per Graph 3 Graph Analysis?
WARNING
Action
Action
https://www.truck-manuals.net/
DIAGNOSTIC MANUAL
Decision
Go to step 8B
Decision
Yes: Go to step 8C
No: Diagnose and repair low fuel rail
pressure (See Performance Diagnostics
section in Engine Diagnostic Manual).
After repairs are complete, retest for
original problem.
99