Navistar MaxxForce DT Diagnostic Manual page 138

Aftertreatment symptom-based diagnostic and inspection manual
Hide thumbs Also See for MaxxForce DT:
Table of Contents

Advertisement

DIAGNOSTIC MANUAL
Actions:
1. After DOC reaches operating temperature and stabilizes (see callout 2, graph 8), verify DOCOT
and DPFOT signal values are greater than 900°F (482°C). In this graph, DOCOT and DPFOT
are less than 900°F (482°C).
2. Verify Diesel Oxidation Catalyst Inlet Temperature (DOCIT) signal value is between 550°F (287°C)
to 800°F (427°C).
NOTE – It is normal to see Diesel Oxidation Catalyst Inlet Temperature DOCIT, DOCOT, and DPFOT signal
values to fluctuate at the beginning and end of the OBFCT.