Follow these recommendations for copper data cabling in high electrical noise envi-
ronments:
•
•
•
1.5.3
Supported Fiber Optic Cables
The following fiber optic cable types are supported under the stated conditions.
Cable Type
Wavelength (nm)
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
RUGGEDCOM RSG2100
Installation Manual, 03/2020, C79000-G8976-1040-17
Data cable lengths should be as short as possible, preferably 3 m (10 ft) in
length. Copper data cables should not be used for inter-building communica-
tions.
Power and data cables should not be run in parallel for long distances, and
should be installed in separate conduits. Power and data cables should intersect
at 90° angles when necessary to reduce inductive coupling.
Shielded/screened cabling can be used when required. Care should be taken to
avoid the creation of ground loops with shielded cabling.
Modal Band-
width (MHz·km)
850
200
1300
500
850
500
1300
500
850
1500
1300
500
850
3500
1300
500
1.5.3 Supported Fiber Optic Cables
Distance (m)
100Base-FX
1000Base-SX
—
275
2000
—
550
2000
—
550
2000
—
550
2000
Introduction
10GBase-SR
33
—
—
82
—
—
300
—
—
400
—
—
5