Certification
6.2 EMC and Environmental Type Tests
Damped Os-
cillatory Mag-
netic Field
Environmental Type Tests
60068-2-1
60068-2-2
60068-2-30
60068-21-1
60068-21-2
60068-2-78
60068-2-14
60255-21-2
60255-21-3
46
Description
Enclosure Ports
Test
IEC
Cold Temperature
IEC
Dry Heat
IEC
Humidity (Damp
Heat, Cyclic)
IEC
IEC
IEC
Humidity (Damp
Heat, Steady State)
IEC
Change of Temperature
IEC
IEC
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Cab
Test Nb
Bump
Seismic
Test Levels
100 A/m
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2g @ 10-150 Hz
30 g @ 11 ms
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
5 Cycles, -40 to 85°
C (40 to 185° F)
10 g @ 16 ms
Method A, Class 2