Cornelius Ribbon Operator's Manual page 54

Postmix tower
Hide thumbs Also See for Ribbon:
Table of Contents

Advertisement

Fault
Only syrup is being
dispensed
Soda/syrup ratio is
incorrect
Insufficient amount
of CO2 in the bev-
erage
Notice!
Crushed ice in the cup may also cause dispensing problems.
When the finished beverage comes into contact with sharp-edged ice,
CO2 is released from the dispensed beverage.
Operator manual: Postmix tower
Ribbon
52
Probable cause
Shut-off valve or pressure-reduc-
ing valve for the fresh water sup-
ply is closed
Fault or error on the undercounter
cooler
Too little/too much soda
Too little/too much syrup
CO
feed pressure for the syrup
2
circuit is set incorrectly on the rel-
evant pressure-reducing valve
CO
pressure for soda is set
2
incorrectly on the relevant pres-
sure-reducing valve
Fault or error on the undercounter
cooler
CO
supply is contaminated
2
6 Errors and malfunctions
Remedy
Open the shut-off valve and pres-
sure-reducing valve for the fresh
water supply (see documentation
on the drinking water system)
See the document "Undercounter
cooler operator manual"
Check the flow setting for soda
(see chapter 4.3.2.2, page 27)
Check the flow setting for the rele-
vant product (see chapter 4.3.2.2,
page 27)
Adjust the CO
feed pressure to
2
the required value (see documen-
tation on the CO
system)
2
Correctly adjust the CO
sure for soda on the relevant
pressure-reducing valve (see doc-
umentation on the CO
See the document "Undercounter
cooler operator manual"
Please contact your service part-
ner
Cornelius Deutschland GmbH
Document no. TD0000000
Version: 19/10/2017, Index 3
pres-
2
system)
2