Specifications - ClipperCreek LCS Series User Manual

With isolation monitor for 230vac
Hide thumbs Also See for LCS Series:
Table of Contents

Advertisement

LCS 230VAC Isolation Monitor User's Manual

SPECIFICATIONS

Line Input Power
Voltage & Wiring
Service
Conductors
Voltage Range
Frequency
Current
Output Power
Dimensions
Height
Width
Depth
Weight
Environment
Agency Approvals
230V AC single-phase - Line, Neutral, and Protective Earth.
This product is designed for use on the 230VAC TN-S, TN-C,
and TN-C-S earthing systems.
Line, Neutral, and Protective Earth use 12AWG, 75ºC copper
wire.
185V AC to 264V AC
50 Hz
LCS-Model
LCS-15
LCS-20
LCS-25
LCS-30
Note that the maximum current for the vehicle is set by the
duty cycle of the Pilot waveform.
Variable depending upon the LCS model and vehicle demand.
At 230V AC, the LCS-15 outputs approximately 2.9KW, the
LCS-20 3.8KW, LCS-25 4.8KW, and the LCS-30 5.5KW.
Dimensions are for the enclosure only.
280 mm (11 in)
100 mm (4 in)
80 mm (3 in)
2.7kg (6lbs) with SAE-J1772
Operating Temperature
Enclosure Rating
FCC Part 15 Class B
Circuit Breaker
15A
20A
25A
30A
connector and 20' cable
TM
30°C (-22°F) to +50°C (+122°F)
NEMA 4X - watertight
Page 10
Maximum Current
12A
16A
20A
24A