Chassis Mounting Flanges Physical Specifications
(Optional)
Table 6-2 Chassis Mounting Flange Physical Dimensions (cont.)
Specification
Width

AC Power Supply Specifications

Table 6-3 AC Power Supply Specifications (cont.)
Specification
Voltage
Frequency
Current
Cable
Power
Type

Power Supply Input Circuit Fuse Requirements

Table 6-4 Acme Packet 1100 Power Supply Input Circuit Fuse Requirements (cont.)
Power Circuit
120 VAC
240 VAC

Environmental Specifications

For the Acme Packet 1100 to function properly, Acme Packet recommends that you follow the
environmental guidelines in the following table.
Table 6-5 Acme Packet 1100 Environmental Specifications (cont.)
Specification
Temperature
Relative Humidity

Chassis Mounting Flanges Physical Specifications (Optional)

Description
3.875 in (9.8425 cm) (each)
Fuse Rating
Autoranging 100 AC to 240 AC wide input with power factor correction
50/60 Hz
12v x 0.75A
2.0 m 18 AWG three-wire cable with three-lead IEC 320 receptacle on the power
supply end and a country-dependent plug on the power source end
300 VA maximum
External, field-replaceable
Fuse Rating
15 AMP
7.5 AMP
Description
The Acme Packet 1100 is required to operate within the temperature
range of:
32° F to 104° F (+0° C to +40° C) (operating)
-4° F to 149° F (-20° C to +65° C) (storage)
10% to 85%, non-condensing
Chapter 6
Power cable size
18 AWG
18 AWG