DISPLAY
DATA
Foto
CFCh
no
Ch
Fot.i
no
AP.Ch
Ft.tE
no - Si
CoS1
no
AP
APCh
CoS2
no
Ch
APCh
Co.tE
no
rESi
Foto
riLA
0
1 - 10
FinE
no
Si
DESCRIPTION
Exterior photocell input
This menu makes it possible to enable the exterior photocell input, i.e.
inactive during opening (see the section regarding installation).
Input enabled even at standstill gate too: the opening movement does not
start if photocell is interrupted
Input disabled (ignored by the control unit)
Input enabled for the closing phase only.
WARNING: if you select this option, you must disable photocell test
Interior photocell input
This menu makes it possible to enable the interior photocell input, i.e.
active during opening and closing (see the section regarding installation).
Input disabled (ignored by the control unit)
Input enabled
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon (fixed ribbons)
Input disabled (ignored by the control unit)
Input enabled during the opening and disabled during the closure
Input enabled in opening and closure
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to
say mobile ribbons
Input disabled (ignored by the control unit)
Input enabled during closure and disabled during opening
Input enabled in opening and closure
Test of the safety edges
This menu allows setting the method of control of the safety edges working
Test disabled
Test enabled for conductive rubber safety edges
Test enabled for optical safety edges
Motor Release on Mechanical Stop
When the gate halts against the mechanical stop, the motor is controlled for a
fraction of a second in the opposite direction, decreasing the motor gear
tension
Function disabled
Time motor release (max. 1 second)
End of Programming
This menu allows to finish the programming (both default and personalized)
saving the modified data into memory
Do not quit the programming
Exit from the programming menu, storing the parameters set