V2 Zariss Series Manual page 48

Irreversible electromechanical pivotingarm actuator for swing gates
Hide thumbs Also See for Zariss Series:
Table of Contents

Advertisement

Available languages

Available languages

5.2 - USE OF THE KEYS FOR PROGRAMMING
The control unit functions and times are programmed by means
of a special configuration menu, which can be accessed and
explored by using the 3 keys, , i and OK, located on the side of
the control unit display.
PLEASE NOTE: Outside the configuration menu, pressing
key activates the START command, pressing the i key
the
activates the PEDESTRIAN START command.
In the manual, the control unit programming procedure is
represented by block diagrams, consisting of the various display
views.
The various blocks include symbols showing the user the keys to
be pressed to navigate around the menu.
When a time is written to the side of the symbol, this means the
key should be pressed and held for the length of time indicated.
6 - INITIALISING THE CONTROL
UNIT
This operation is necessary when the control unit is installed for
the first time, and is used to define the gate leaf starting order
and the direction of rotation of the two motors.
Until initialisation is performed, it is not possible to operate the
gate or program the control unit.
The initialisation procedure steps are as follows:
1. Starting initialisation
2. Selecting the superior and inferior gate leaves
3. Selecting the opening direction
4. Verifying Slave motor connection
5. Self-training the working times
Start
Main screen
Press and hold OK for approx. 2 seconds, until the message "-ini" appears. On release of the key, the message GO appears.
Pressing OK starts the procedure. The arrow keys can be used to select "ESC", thus exiting without starting the procedure.
The following table describes the functions of the push-buttons:
Press and release the push-button OK
Keep pressed the push-button OK for 2 seconds
Release the push-button OK
Press and release the push-button
Press and release the push-button i
WARNING:
• Ensure that the motors and accessories are connected correctly
prior to performing initialisation
• Position the gate leaves roughly at the half way points (unblock
the motors, operate the gate leaves, re-block the motors)
• Firstly, the procedure will involve short movements of the gate
leaves. In the final phase, the gate is moved through its entire
path. The operator should be positioned so as not to interfere
with the movement of the gate leaves and so as not to trip any
photocells
• Installation is automatically interrupted if no operations are
performed for one minute
• The initialisation procedure involves the loading of default
values for all programming menu parameters
Starting initialisation
The control unit moves the Master motor first in one direction,
then in the other, 3 times
Exit (initialisation incomplete)
46

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zariss-mZariss-s

Table of Contents