V2 ZARISS-M Manual

V2 ZARISS-M Manual

Irreversible electromechanical pivoting arm actuator for swing gates
Hide thumbs Also See for ZARISS-M:

Advertisement

Quick Links

ATTUATORE ELETTROMECCANICO IRREVERSIBILE
I
A BRACCIO SNODATO PER CANCELLI A BATTENTE
IRREVERSIBLE ELECTROMECHANICAL PIVOTING
GB
ARM ACTUATOR FOR SWING GATES
ACTIONNEUR ÉLECTROMÉCANIQUE IRRÉVERSIBLE
F
AVEC BRAS ARTICULÉ POUR PORTAILS BATTANTS
ACTUADOR ELECTROMECÁNICO IRREVERSIBLE
E
DE BRAZO ARTICULADO PARA CANCELAS BATIENTES
V2 S.p.A.
Corso Principi di Piemonte, 65/67
12035 RACCONIGI (CN) ITALY
tel. +39 01 72 81 24 11 - fax +39 01 72 84 050
info@v2home.com - www.v2home.com
Zariss
IL n. 341-1
EDIZ. 27/04/2011

Advertisement

Table of Contents
loading

Summary of Contents for V2 ZARISS-M

  • Page 1 V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY IL n. 341-1 tel. +39 01 72 81 24 11 - fax +39 01 72 84 050 EDIZ. 27/04/2011 info@v2home.com - www.v2home.com Zariss ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE...
  • Page 3: Table Of Contents

    INDEX 1 - GENERAL SAFETY INFORMATION............................42 1.1 - PRELIMINARY CHECKS and IDENTIFICATION OF THE TYPE TO BE USED ..............42 1.2 - TECHNICAL ASSISTANCE SERVICE ..........................43 1.3 - EC DECLARATION OF INCORPORATION FOR PARTLY COMPLETED MACHINERY ............43 2 - TECHNICAL DATA................................44 3 - INSTALLATION OF THE MOTOR ............................44 3.1 - INSTALLATION LAYOUT ............................44 3.2 - INSTALLATION MEASURES ............................45...
  • Page 4: General Safety Information

    • In the event of interventions on automatic or differential breakers or fuses, it is essential that faults be identified and resolved prior to resetting. In the case of faults that cannot be resolved using the information to be found in this manual, consult the V2 customer assistance service.
  • Page 5: Technical Assistance Service

    1.3 - EC DECLARATION OF INCORPORATION FOR PARTLY COMPLETED MACHINERY (DIRECTIVE 2006/42/EC, ANNEX II-B) The manufacturer V2 S.p.A., headquarters in Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy Under its sole responsibility hereby declares that: the partly completed machinery model(s):...
  • Page 6: Technical Data

    -20 ÷ +55 Working cycle Motor weight Protection 3 - INSTALLATION OF THE MOTOR 3.1 - INSTALLATION LAYOUT ZARISS-M actuator cable 3 x 1 mm Digital radio switch ZARISS-S actuator cable 3 x 1,5 mm cable 4 x 0,5 mm...
  • Page 7: Installation Measures

    to ensure the best automation performance, the measurement levels shown in the following table shall be complied with. Change the gate structure to adapt it to one of the cases in the table, if necessary. 1. Depending on the opening angle of the leaves or panels, make sure it is possible to respect the dimensions reported in the table 2.
  • Page 8: Installation Of The Motor

    To install the ZARISS motor, follow the following steps closely: 1. Fix bracket A to the pillar using rawplugs suited to the pillar material 5. Fit the curved arm G onto the straight arm C using the PLEASE NOTE: the bracket should be perfectly horizontal. pivot-pin I and snap-ring L Use a spirit level to accurately position the bracket 6.
  • Page 9: Motor Unblocking

    3.4 - MOTOR UNBLOCKING In the case of a power failure, the gate can be unblocked by operating the motor: 1. Open the lock cover J located on the front of the motor 2. Insert the key L into the hole and turn clockwise until reaching the end-stop To reset the automation device, proceed as follows: 1.
  • Page 10: Control Unit

    with power disconnected. PD12 is provided with a display that, not only makes programming simple, but also allows a continuous monitoring of the input statuses; in addition, thanks to a menu structure, the 4.3 - CONNECTION OF THE MOTOR working schedule and the operation logic can be set easily. The control unit is supplied already connected to the MASTER motor.
  • Page 11: External Photocell Connection

    PHOTOCELLS - INSTRUCTIONS SAFETY RIBBONS - INSTRUCTIONS • The control unit powers the photocells at a nominal voltage of • If several edges, with normally closed contacts, are used, the 24 Vdc, with an electronic fuse that breaks the current in the outputs should be connected in series.
  • Page 12: Activation Inputs

    operation depends on the programmed operation modes immediate gate stop when activated. This switch must have a (see Strt item of programming menu): normally close contact (NC) that will get open in case of operation. • Standard mode: a command being on the first input will In case the STOP switch is operated while the gate is open, the cause the complete opening of the gate (start);...
  • Page 13: Lock

    The ADI (Additional Devices Interface) interface of the control unit PD12 allows the connection to V2 optional modules. Refer to V2 catalogue or to the technical sheets to see which optional modules with ADI interface are available for this control unit.
  • Page 14: Electrical Connection Summary

    Phase power supply 230Vac Earth Neutral power supply 230Vac...
  • Page 15: Control Panel

    5.1 - DISPLAY B1 - B2 230Vac courtesy or flashing lights When power is on, the control unit checks that display correctly 8.8.8.8. Motor 2 (+) operates by switching on all segments for 1.5 sec. Pr I.0 Firmware version, e.g. , will be viewed in the following Motor 2 (ground) 1.5 sec.
  • Page 16: Use Of The Keys For Programming

    The control unit functions and times are programmed by means The following table describes the functions of the push-buttons: of a special configuration menu, which can be accessed and and OK, located on the side of explored by using the 3 keys, , Press and release the push-button OK the control unit display.
  • Page 17 the gate leaf in motion is the leaf that should open first the gate leaf in motion is the leaf that should open second PLEASE NOTE: if installation envisages one motor only, select Select this parameter depending on the direction of opening of gate leaf 1 the gate leaf is opening the gate leaf is closing Having selected this parameter, the control unit moves the SLAVE...
  • Page 18: Accessing The Control Unit Settings

    UNIT SETTINGS Rapid configuration is a menu allowing the main control unit parameters to be programmed with a few operations. Once initialisation is performed (even without time self-training), it will be possible to access the various control unit functions, It is essential the initialisation procedure has already been including initialisation itself.
  • Page 19: Power Adjustment

    This rapid configuration menu option allows the motor power to be adjusted. The value displayed is the value currently set. Using keys, select the value to be set and press OK to confirm and continue. ÷ Values from 30 (minimum) to 100 (maximum). Equal values for both motors PErS Customised configuration: if the display shows...
  • Page 20: Operational Logic

    This rapid configuration option is used to define the start command action (from the terminal board, from the remote control or from the keypad) The possible options are: P - P Step Logic - the Start command results in opening, stop, closure, stop, in sequence. AUto Automatic logic - the Start command is used to open the gate.
  • Page 21: Loading The Default Parameters

    If necessary, it is possible to restore all parameters to their standard or default values (see the final summary table). PLEASE NOTE: This procedure results in the loss of all customised parameters, and hence it has been included outside the configuration menu, in order to minimise the likelihood of it being run in error.
  • Page 22: Working Time Self-Training

    This menu allows automatic learning of the times required for the gate to open and close. During this phase, the control unit also records the forces required to open and close the gate: these values will be used by activating the obstacle sensor.
  • Page 23: Reading Of Cycle Counter

    COUNTER thousands, any following pressure will have the setup be increased or decreased of 1000 units. The previous PD12 control unit counts the completed opening cycles of the displayed count will get lost. gate and, if requested, it shows that service is required after a fixed number of cycles.
  • Page 24: Programming The Control Unit

    CONTROL UNIT The configuration menu -PrG consists in a list of configurable items; the display shows the selected item. each time you press key, current time value increases of half a By pressing , you will pass to the next item; by pressing , you minute;...
  • Page 25 Enabling Energy Saving If this function is enabled, the control unit enters ENERGY SAVING mode in accordance with the description in the dedicated section on page 48. Function enabled Function not enabled Partial opening time (pedestrian access) If a Pedestrian Start command is received, the control unit opens the SUPERIOR gate leaf only, for as reduced period of time.
  • Page 26 Gate leaf delay during closing During closing, the SUPERIOR gate leaf starts to move after the INFERIOR gate leaf, with a delay equal to the length of time set by this menu. Lock time Before the opening phase begins, the control unit will energize the electric lock in order to release it and enable the gate motion.
  • Page 27 Pre-blinking time t.PrE Before any gate movement, blinker will be activated for time, to warn about the incoming motion. Motor 1 power This menu allows adjusting the motor 1 power. The displayed value is the percentage of max. motor power. Motor 2 power This menu allows adjusting the motor 2 power.
  • Page 28 During battery operation, the controller is powered with a lower voltage compared to mains power. For this reason, the power of the motors is reduced compared to normal operation and may not be sufficient to move the gate panels effectively. This menu allows you to activate the motors at their maximum power during battery operation.
  • Page 29 Braking In the final section of the trip, the control unit drives the motor at Po.r1 reduced power, depending on the values set for parameters Po.r2 In this menu, it is possible to adjust the duration of the braking phase. The value set is the percentage of the total trip, and is equal for both motors during opening and closing.
  • Page 30 Start command during the pause This menu allows fixing the control unit conduct in case it receives a Start command when the gate is open during its pause phase. ChiU the gate starts closing command is ignored PAUS Ch.AU The pause time is reset ( ChiU Select option , to set up the “step-by-step”...
  • Page 31 Pause after transit In order to let the gate open for the shortest possible time, it is possible to stop the gate once the passage before the photocells is detected. If Ch.tr the automatic working is enabled, the time of the pause is If interior and exterior photocells are installed, the gate only pauses after passing in front of both has been detected.
  • Page 32 Setting low voltage exit lights This menu makes to possible to set the flashing exit function. Not used FLSh Flasher operation (fixed frequency) Indicator light operation: Indicates the status of the gate in real-time. The type of blinking indicates the four possible conditions: - GATE STOPPED: Light off - GATE IN PAUSE: the light is on, fixed...
  • Page 33 Otherwise, it will stand still and the flashing light will stay onfor 5 sec. The whole test cycle lasts less than one second. WARNING: V2 suggests to keep activated the test of the photocells in order to grant a higher safety of the system.
  • Page 34 This menu allows setting the method of control of the safety edges working. Test disabled Foto Test enabled for optical safety edges rESi Test enabled for conductive rubber safety edges WARNING: V2 suggests to keep activated the test of the photocells in order to grant a higher safety of the system.
  • Page 35 End of Programming This menu allows to finish the programming (both default and personalized) saving the modified data into memory. Further corrections to carry out: do not quit the programming. changes complete: when programming is complete and the data is saved, the display shows the control panel THE INSERTED DATA HAVE BEEN MEMORIZED: THE CONTROL UNIT IS READY TO BE USED.
  • Page 36: Summary Of Functions

    MEMO DISPLAY DATA DESCRIPTION DEFAULT DATA En.SA no / Si Enabling ENERGY SAVING t.APP 0.0” ÷ 1’00 6.0” Partial opening time (pedestrian access) t.ChP 0.0” ÷ 1’00 7.0” Partial closing time (pedestrian access) r.AP 0.0"÷ 1’.00 1.0’’ Gate leaf delay during opening r.Ch 0.0"...
  • Page 37 MEMO DISPLAY DATA DESCRIPTION DEFAULT DATA LUCi CiCL Courtesy lights t.LUC - Timed function (from 0 to 20’) - Function deactivated CiCL - On for the entire duration of the cycle Auxiliary channel - Timed function (from 0 to 20’) biSt - Bistable operation - Monostable operation...
  • Page 38: Operation Defects

    Err9 It means that triac test failed. Before sending the control unit to V2 S.p.A. for repair, be sure It means that programming was locked by means of the that motors have been properly connected.
  • Page 39 control unit fails the exterior photocell test, Er91 the display shows the message Check the photocell connected to the PHOTO input is working. PLEASE NOTE: This abnormality does not delete data acquired using the initialisation procedure Error 92 If, during the initialisation procedure, the control unit detects an obstacle during movement of the gates, the display shows Er92...
  • Page 40: Testing And Start-Up

    V2 recommends the application of the following technical The recommended interval between each maintenance operation standards: is six months, the checks involved should at least relate to: •...
  • Page 41: Disposal

    Are you satisfied? Should you wish to add another automation device to your home, contact the same installer and ask for a V2 SpA product: we guarantee you the most advanced products on the market and maximum compatibility with existing automation devices.

This manual is also suitable for:

Zariss seriesZariss-s

Table of Contents