V2 Zariss Series Manual page 59

Irreversible electromechanical pivotingarm actuator for swing gates
Hide thumbs Also See for Zariss Series:
Table of Contents

Advertisement

Available languages

Available languages

DISPLAY
DATA
St.AP
PAUS
ChiU
no
St.Ch
StoP
APEr
St.PA
ChiU
no
PAUS
SPAP
PAUS
ChiU
no
Ch.AU
no
0.5"-20.0'
Ch.tr
no
0.5"-20.0'
PA.tr
no - Si
DESCRIPTION
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase
The gate stops and goes to pause
The gate immediately starts closing
The gate go on with the opening phase (command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase
The gate stops and its cycle is considered as finished
The gate opens again
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase
The gate starts closing
Command is ignored
Ch.AU
The pause time is reset (
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase
The gate stops and goes to pause
The gate immediately starts closing
The gate goes on with the opening phase (command is ignored)
Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu
Function deactivated
The gate recloses after the set period time
(adjustable time from 0.5" to 20.0')
Closing after transit
During the automatic operation, the pause count down starts from the set up
value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be immediately
stored as pause time.
This function allows having a fast closing as soon as transit through the gate is
completed, therefore, a time shorter than Ch.AU is generally used.
Ch.AU
will be used when no is set up.
Function deactivated
The gate recloses after the set period time
(adjustable time from 0.5" to 20.0')
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is
)
Ch.tr
57
DEFAULT MEMO
PAUS
StoP
ChiU
PAUS
no
no
no