V2 Zariss Series Manual page 57

Irreversible electromechanical pivotingarm actuator for swing gates
Hide thumbs Also See for Zariss Series:
Table of Contents

Advertisement

Available languages

Available languages

DISPLAY
DATA
EnSA
no
Si
t.APP
0.0" - 1'00
t .ChP
0.0" - 1'00
r.AP
0.0" - 1'00
r.Ch
0.0" - 1'00
t.SEr
0.5" - 1'00
no
SEr.S
Si
no
t.ASE
0.5" - 1'00
t.inv
no
0.5" - 1'00
DESCRIPTION
Enabling Energy Saving
Function not enabled
Function enabled
Partial opening time (pedestrian access)
If a Pedestrian Start command is received, the control unit opens the SUPERIOR
gate leaf only, for as reduced time (adjustable time from 0.0" to 1'00)
Partial closing time (pedestrian access)
In the case of partial opening, the control unit uses this time for closing.
The maximum time that can be set is equal to the closing time for the
SUPERIOR gate leaf (adjustable time from 0.0" to 1'00).
NOTE: The avoid the gate leaf not closing completely, it is recommended a
longer time be set than that used for opening
Gate leaf delay during opening
During opening, the INFERIOR gate leaf starts to move after the SUPERIOR
gate leaf, with a delay equal to the length of time set by this menu
(adjustable time from 0.0" to 1'00).
r.AP
NOTE: If
is set to 0, the control unit does not check the correct closing
order of the gate leaves
Gate leaf delay during closing
During closing, the SUPERIOR gate leaf starts to move after the INFERIOR gate
leaf, with a delay equal to the length of time set by this menu (adjustable time
from 0.0" to 1'00)
Lock time
Before the opening phase begins, the control unit will energize the electric
lock in order to release it and enable the gate motion (adjustable time from
0.0" to 1'00)
Function deactivated
Silent Locking Mode
Silent Mode (100 Hz)
WARNING: In some cases, there may be problems when unlocking.
If problems should occur, select the Standard mode
Standard Mode (50 Hz)
Lock advance time
While the electric lock is energized, the gate will stay standstill for
time (adjustable time from 0.5" to 1'00), to make its release easier.
WARNING: in case the gate has no electric lock, set the value 0
Backlash time
It could be useful to give a closing command to motors, to help the
electric lock release
Function deactivated
The control unit controls the motors in reduced power in closing
direction for the setup time (adjustable time from 0.5" to 1'00).
NOTE: the backlash precedes the electric lock release. It is possible to reverse
the order by setting a lock advance time higher then the backlash one.
WARNING: in case the gate has no electric lock, set the value 0.
t.APP
55
DEFAULT MEMO
no
8.0"
9.0"
1.0"
5.0"
2.0"
Si
1.0"
t.ASE
no