DISPLAY
DATA
t.PrE
0.5" - 1'00
no
Pot1
30 - 100
Pot2
30 - 100
Po.r1
0 - 60
Po.r2
0 - 60
P.bAt
no
Si
rAM
0 - 4
SEn1
1.0A - 3.5A
SEn2
1.0A - 3.5A
rALL
30 - 100
DESCRIPTION
Pre-blinking time
Before any gate movement, blinker will be activated for
about the incoming motion (adjustable time from 0.5" to 1'00)
Function deactivated
Motor 1 power
The displayed value is the percentage of max. motor power
Motor 2 power
The displayed value is the percentage of max. motor power
Power Motor 1 during slow-down phase
The displayed value is the percentage of max. motor power
Power Motor 2 during slow-down phase
The displayed value is the percentage of max. motor power
Maximum motor power during battery operation
During battery operation, the controller is powered with a lower voltage
compared to mains power. For this reason, the power of the motors is
reduced compared to normal operation and may not be sufficient to
move the gate panels effectively.
This menu allows you to activate the motors at their maximum power
during battery operation.
Motor power at the parameters set in the
Maximum motor power
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
Adjusting the obstacle sensor on motor 1
This menu allows adjustment of the sensitivity of the obstacle sensor for
motor 1. When the current absorbed by the motor exceeds the value
set, the control unit detects an alarm.
For sensor operation, please refer to the chapter 8.2
Adjusting the obstacle sensor on motor 2
This menu allows adjustment of the sensitivity of the obstacle sensor for
motor 2. When the current absorbed by the motor exceeds the value
set, the control unit detects an alarm.
For sensor operation, please refer to the chapter 8.2
Braking
In the final section of the trip, the control unit drives the motor at reduced
power, depending on the values set for parameters
In this menu, it is possible to adjust the duration of the braking phase.
The value set is the percentage of the total trip, and is equal for both
motors during opening and closing.
t.PrE
Pot1
Pot2
and
menus
Po.r1
and
56
DEFAULT MEMO
1.0"
time, to warn
70
70
30
30
no
4
1.5A
1.5A
30
Po.r2
.