V2 AYROS-24V Manual
Hide thumbs Also See for AYROS-24V:

Advertisement

AYROS-24V
I
ATTUATORE ELETTROMECCANICO
IRREVERSIBILE 24V PER CANCELLI
SCORREVOLI FINO A 1000 KG
DI PESO
GB
24V ELECTRO-MECHANICAL
IRREVERSIBLE RACK ACTUATOR
FOR SLIDING GATES UP TO 1000 KG
F
OPERATEUR ELECTROMECANIQUE
IRREVERSIBLE 24V POUR PORTAILS
COULISSANTS JUSQU'A 1000 KG
DE POIDS
E
MOTOR ELECTROMECANICO
IRREVERSIBLES 24V PARA PUERTAS
CORREDERAS HASTA 1000 KG
DE PESO
ZIS334
IL 393-1
EDIZ. 22/08/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AYROS-24V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for V2 AYROS-24V

  • Page 1 ZIS334 IL 393-1 EDIZ. 22/08/2018 AYROS-24V ATTUATORE ELETTROMECCANICO IRREVERSIBILE 24V PER CANCELLI SCORREVOLI FINO A 1000 KG DI PESO 24V ELECTRO-MECHANICAL IRREVERSIBLE RACK ACTUATOR FOR SLIDING GATES UP TO 1000 KG OPERATEUR ELECTROMECANIQUE IRREVERSIBLE 24V POUR PORTAILS COULISSANTS JUSQU’A 1000 KG...
  • Page 2 334 mm 343 mm 50 mm 160 mm 206 mm 283 mm 343 mm...
  • Page 3: Table Of Contents

    INDEX 1 - GENERAL SAFETY INFORMATION ........................1.1 - PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED ............1.2 - TECHNICAL ASSISTANCE SERVICE ........................1.3 - EU DECLARATION OF CONFORMITY ....................... 2 - TECHNICAL DATA ..............................3 - INSTALLATION OF THE MOTOR ..........................3.1 - INSTALLATION OF THE MOTOR ........................
  • Page 4: General Safety Information

    V2 customer assistance service. 1 - GENERAL SAFETY INFORMATION • V2 declines all responsibility for failure to comply with good construction practice standards in addition to structural deformation of the gate that might occur during use.
  • Page 5: Preliminary Checks And Identification Of The Type To Be Used

    1.1 - PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED The automation device should not be used until installation, as specified in “Testing and start-up”, has been performed. It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and verify that:...
  • Page 6: Technical Assistance Service

    Electromagnetic Compatibility Directive 2014/30/EU 2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B Directive ROHS2 2011/65/CE The manufacturer V2 S.p.A., headquarters in Corso Principi di The relevant technical documentation is available at the national Piemonte 65, 12035, Racconigi (CN), Italy authorities’ request after justifiable request to: V2 S.p.A.
  • Page 7 WARNING: The following chart indicates the recommended maximum speed that can be programmed (via the Parameter) depending on door weight WARNING – DO NOT EXCEED THE INDICATED MAXIMUM SPEED AYROS500-24V-F 40,00 35,00 30,00 25,00 20,00 15,00 10,00 Gate weight [kg] AYROS600-24V 26,00 24,00...
  • Page 8: Installation Of The Motor

    3 - INSTALLATION OF THE MOTOR 5. Wait for the complete setting of the concrete 6. Unscrew the bolts fixing the base to the clamps and put the motor on the plate 3.1 - POSITIONING OF THE MOTOR 7. Adjust the 4 grains to make the motor be perfectly levelled 8.
  • Page 9: Mounting The Rack

    3.2 - MOUNTING THE RACK 1. Release the motor and turn the gate completely open. 2. Fix all the rack elements to the gate, making sure that they stand at the same height than the motor pinion. The rack MUST BE positioned 1 or 2 mm over the pinion of the motor all the gate length.
  • Page 10: Installing The Magnetic Limit Switches

    3.4 - INSTALLING THE MAGNETIC LIMIT SWITCHES The supplied magnets have been colored differently in order to be WARNING: For your safety, it is necessary that the gate distinguished from each other: is equipped with mechanical stoppers. If the gate is not equipped with these stoppers, an erratic BLUE MAGNET = RIGHT LIMIT SWITCH (DX) movement past the range limit may cause the gate to fall.
  • Page 11: Motor Overriding System

    3.5 - MOTOR OVERRIDING SYSTEM In case of absence of current, the gate can be released by operating on the motor: 1. Open the hatch of the lock J in front of the motor 2. Insert the key K in the lock and turn clockwise to open the hatch of the release on the side 3.
  • Page 12: Installation Layout

    3.6 - INSTALLATION LAYOUT COMPONENTS ADDITIONAL ACCESSORIES Motor Key switch Transmitter Pillar photocells Receiving module Pillar-mounted digital radio switch Photocells Safety edges Flashing light WES-ADI module (via radio management of edges) WES sensors LENGTH OF THE CABLE < 10 metres from 10 to 20 metres from 20 to 30 metres Power supply 230V/120V...
  • Page 13: Battery Power

    4 - CONTROL UNIT 4.2 - BATTERY POWER PD14 is provided with a display that, not only makes In the case of an electricity black-out, the device may be powered programming simple, but also allows a continuous monitoring of using a battery pack (accessory code 161212). the input statuses;...
  • Page 14: Control Unit

    4.3 - ACTIVATION INPUTS 4.4 - STOP PD14 control unit is equipped with two activation inputs (START For a better safety, you can fit a stop switch that will cause the and START P.), whose operation depends on the programmed immediate gate stop when activated.
  • Page 15: Connecting Safety Ribbons

    4.7 - LOW VOLTAGE LIGHT OUTPUT SAFETY RIBBONS - REMARKS The PD14 control unit has a 24 VDC output that allows • If several edges, with normally closed contacts, are used, the connection of a maximum load of 3W. outputs should be connected in series. This output can be used to connect a warning light, indicating the •...
  • Page 16: Adi Interface

    PD14 allows the connection to V2 optional modules. traditional devices with N.O. contact Refer to V2 catalogue or to the technical sheets to see which WARNING: If you use maintained optional modules with ADI interface are available for this control command devices (magnetic loop detectors, unit.
  • Page 17 24Vdc OVERLOAD RECEIVER E3 E4 B1 B2 A1 A2 24 Vdc BATTERY POWER SUPPLY ACCESSORIES F1 = 2,5A (230V) 4A (120V) MAINS - 43 -...
  • Page 18: Control Panel

    5 - CONTROL PANEL 5.2 - USE OF THE KEYS FOR PROGRAMMING The control unit functions and times are programmed by means 5.1 - DISPLAY of a special configuration menu, which can be accessed and explored by using the 3 keys, and OK, located on the side of When power is on, the control unit checks that display correctly the control unit display.
  • Page 19: Accessing The Control Unit Settings

    6 - ACCESSING THE CONTROL UNIT SETTINGS 8 - LOADING THE DEFAULT PARAMETERS If necessary, it is possible to restore all parameters to their 1. Press and hold the OK key until the display shows the menu standard or default values (see the final summary table). desired 2.
  • Page 20: Installation Menu

    9 - INSTALLATION MENÙ (SEt) 9.2 - MANUAL HANDLING This menu allows you to perform the movements of the gate WARNING: when this procedure is activated the needed during installation. safeties are not active. 5. The display shows The automatic learning procedure enables to save run limits based on data collected by the encoder.
  • Page 21: Emergency Dead Man Operation

    10 - EMERGENCY DEAD MAN OPERATION 11.1 - SIGNAL OF SERVICE REQUIRED This operational mode can be used to move the gate in DEAD As soon as the counter of cycles before the next request for MAN mode in particular cases, such as installation/maintenance or service is zero, the control unit shows the request for service in the case of malfunctioning of photocell, edge, limit switches or through an additional 5-second pre-blinking.
  • Page 22: Programming The Control Unit

    12 - PROGRAMMING THE CONTROL UNIT -PrG The configuration menu consists in a list of configurable items; the display shows the selected item. By pressing , you will pass to the next item; by pressing , you will return to the previous item. FinE By pressing OK, you can view the current value of selected item and possibly change it.
  • Page 23 PARAMETER VALUE DESCRIPTION DEFAULT MEMO Motor power (STD) (FAST) 30 - 100 The displayed value is the percentage of max. motor power P.rAL Power motor during slow-down phase 0 - 70 The value displayed represents the percentage of the maximum motor power Po.AL Power used for the realignment on the limit...
  • Page 24 PARAMETER VALUE DESCRIPTION DEFAULT MEMO St.PA ChiU Start command during the pause This menu allows fixing the control unit conduct in case it receives a Start command when the gate is open during its pause phase ChiU The gate starts closing Command is ignored PAUS Ch.AU...
  • Page 25 PARAMETER VALUE DESCRIPTION DEFAULT MEMO SPiA FLSh Setting low voltage exit lights This menu makes to possible to set the flashing exit function FLSh Flasher operation (fixed frequency) Not used W.L. Indicator light operation: Indicates the status of the gate in real-time. The type of blinking indicates the four possible conditions: - GATE STOPPED: Light off - GATE IN PAUSE: the light is on, fixed...
  • Page 26 PARAMETER VALUE DESCRIPTION DEFAULT MEMO CoS1 Safety ribbon 1 input This menu allows enabling the input for type 1 safety ribbon, that is to say, fixed ribbons Input disabled (ignored by the control unit) APCh Input enabled in opening and closure Input enabled during the opening and disabled during the closure CoS2 Safety ribbon 2 input...
  • Page 27: Operation Defects

    2. The procedure stops and the displays shows It means that MOSFET test failed. It means that a safety device has tripped. Before sending the control unit to V2 S.p.A. for repair, be sure that motors have been properly connected. Error 9...
  • Page 28: Testing And Start-Up

    V2 recommends the application of the following technical The recommended interval between each maintenance operation standards: is six months, the checks involved should at least relate to: •...
  • Page 29 Are you satisfied? Should you wish to add another automation device to your home, contact the same installer and ask for a V2 SpA product: we guarantee you the most advanced products on the market and maximum compatibility with existing automation devices.
  • Page 30 V2 S.p.A. Corso Principi di Piemonte 65/67 12035 RACCONIGI CN (ITALY) Tel. +39 0172 812411 - Fax +39 0172 84050 info@v2home.com www.v2home.com...