V2 Zariss Series Manual page 49

Irreversible electromechanical pivotingarm actuator for swing gates
Hide thumbs Also See for Zariss Series:
Table of Contents

Advertisement

Available languages

Available languages

Select this parameter depending on the position (superior or inferior) of
the gate leaf in motion
SUP
the gate leaf in motion is the leaf that should open first
inF
the gate leaf in motion is the leaf that should open second
PLEASE NOTE: if installation envisages one motor only, select SUP
Select this parameter depending on the direction of opening of gate leaf 1
AP1
the gate leaf is opening
Ch1
the gate leaf is closing
Having selected this parameter, the control unit moves the SLAVE
motor
1 If the control unit detects the SLAVE motor, the display shows AP2
Select this parameter depending on the direction of opening of gate leaf 2
AP2
the gate leaf is opening
Ch2
the gate leaf is closing
Having selected the parameter, press OK to move to the next phase.
If the display shows Er93, this means the SLAVE motor is connected
incorrectly.
Check the SLAVE motor connection and repeat the initialisation
procedure
2 If the control unit does NOT detect the SLAVE motor, the display
shows SinG
If the installation envisages only one motor, press OK to move to the
next phase.
If the installation envisages two motors, select the doP menu option and
press OK.
The display will show Er94 to indicate that the SLAVE motor is not
connected, or is connected incorrectly.
Check the SLAVE motor connection and repeat the initialisation
procedure
3 If the control unit does not detect a photocell on the PHOTO input,
the display shows Ft.no
If the installation does not envisage the use of a photocell, select Ft.no
and press OK to move to the next phase.
The photocell will be automatically disabled.
If installation envisages the use of a photocell, select Ft.Si and press OK.
The display will show Er91 to indicate that the photocell is not
connected, or is connected incorrectly.
Check the photocell connection and repeat the procedure.
4 If the control unit detects a photocell connected correctly to the
PHOTO input, it automatically switches to the working time
self-training phase.
Press OK to start the self-training phase.
Select ESC and press OK to exit the menu without performing the time
self-training phase.
Please note: in the case of exiting without self-training, it will not
be possible to operate the gate.
In any case, it will be possible to perform self-training in a separate
phase and program the remainder of the control unit functions, using
the specific menu.
47