Deactivating the Infrared Receiver on the Delta-3 and SSD-66 (cont.)
STEP THREE: Next to the microprocessor chip, there are three two-pin headers. Each Delta-
3 and SSD-66 comes from the factory with shunting plugs attached to all three two-pin
headers. These shorting plugs are easily recognizable because they slide over the two-
pin headers. They are used to connect the two pins of each header together, thus
activating the corresponding function labelled on the main printed circuit board.
STEP FOUR: To deactivate the infrared receiver on the front panel, simply remove the
shunting plug covering the "IRR" two-pin header. Note: do not remove the shunting
plugs that are covering the two-pin headers labelled "ADA RX" and "ADA TX." If
there are no shunting plugs covering these headers, make sure to put them on. The
following pictures illustrate this procedure.
IF THE DELTA-3 AND SSD-66 ARE
IF THE VS-3 AND SSD-66
NOT LOCATED WITHIN CLOSE
ARE LOCATED IN A ROOM
PROXIMITY TO THE MC-3000,
OTHER THAN THAT OF THE
ATTACH THE SHUNTING PLUGS
MC-3000
AS SHOWN.
NORMALLY SENT
FROM THE FACTORY
WITH ALL THREE
SHUNTING PLUGS
INSTALLED
STEP FIVE: If you removed any shunting plugs, make sure to put them in a safe place until
you need them. Replace the top cover and screws. It is a good idea to turn the unit
upside-down briefly to make sure that nothing was dropped inside before tightening
the screws.
LEGEND
SHUNTED
(PINS ARE SHORTED TOGETHER)
NOT SHUNTED
(PINS NOT SHORTED TOGETHER)
137
IF THE DELTA-3 AND SSD-66
IF THE VS-3 AND SSD-66
ARE LOCATED WITHIN CLOSE
ARE LOCATED IN THE SAME
PROXIMITY TO THE MC-3000,
ROOM AS THE MC-3000
ATTACH THE SHUNTING PLUGS
AS SHOWN.
REMOVE THE "IRR"
SHUNT FOR NORMAL
SYSTEM TITANUS
INSTALLATION