Warnings - KONTRONIK KOLIBRI 60 LV Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

10.2 Errors during the operation:
If there is an error during the operation, the
KOLIBRI will show you the error like you can see in
the table below.
Operation error: LED green is off, LED red flashes
the issue out:
blink-
description
code
1
Voltage not in operation range
2
Current not in operation range
3
Overtemperature
Voltage or current of the BEC out
4
of the range
Limit of programmed capacity
5
reached
6
No RC Signal
Motor is not able to handle this
7
power
PowerVoltageDetector of the
8
processor has detected
9
No Motor values
26
process
Please check battery /
motor
Please check battery /
motor
Please improve cooling
Please check your
servos
Please check the
connection between
ESC (Master Cable)
and receiver
Please restart your ESC
Please restart your ESC
Please check motor and
connections. Then
restart your ESC

10.3 Warnings

If there is a warning reached, the KOLIBRI shows it
by the following codes:.
LED red and LED green flashing fast = orange
blink-
description
code
1
Variance is too big or RPM not in range
2
Cut Off
3
Limit of battery discharge reached
4
Watchdog Reset has detected
5
Internal error
Programmed undervoltage is reached
6
7
Programmed current limit reached
8
Programmed MOS FET Temperature limit reached
9
Programmed BEC Temperature limit reached
10
programmed BEC current reached
11
Programmed limit of battery discharge reached

Hide quick links: