I
PI-35
OSITION
T
P
4x Ø.39[Ø9.8] Thru
Equally Spaced on a
Ø4.75 [120.7] B.C.
Figure 2-2 Positioner Mounting Hole Pattern (Bottom of Positioner)

2.6 Wiring the System

This section discusses wiring the system assuming the default joystick controller (P/N: 5098901)
is being used.

2.6.1 Positioner Plugs

The positioner has (2) plug locations for wiring as follows (Figure 2-3):
Side Egress (Located on the side of the mounting pedestal)
Bottom Egress (Located on the bottom of the mounting pedestal)
The side egress ships from the factory with a removable plug installed. The bottom egress ships
from the factory with a plug plate installed. To use the bottom egress, the removable plug from
the side egress must be swapped with the plug plate. If any egress is not properly sealed, the
positioner will leak and become damaged voiding the warranty.
View From Side
2-4
Removable
Plug on Side
Egress

Figure 2-3 Positioner Plug Locations

Ø5.51 [Ø140.0]
Plug Plate on
Bottom Egress
View From Beneath
TP-5406201-B
July 2017